background image

This Owner's manual will pr

ovide you with information required to safely own and

operate the QEP 60095 water pump. This pump is carefully inspected and tested to
ensure both safety and operational performance. However, failure to follow the
instructions and warnings in this Owner's manual may result in damage to the 
pump and/or serious injury. Be sure to read and save this Owner's manual for future
reference. Note: Pump is fully submersible.

OPERA

TION:

1.

The 

QEP 60095

water pump must be operated in clean water and can be placed in

any position so long as the intake is below the water level.

2. The weight of the pump must be adequately supported and resting inside the water

tray.

3. The discharge is designed for use with 1/2" ID flexible tubing. An adapter that fits

inside of the discharge is included to allow the use of 3/8" ID flexible tubing.

4. The flow rate on the 

QEP 60095

water pump can be adjusted by r

otating the flow

adjuster located on the front of the pump. Rotate the adjuster counterclockwise to
increase flow and clockwise to decrease flow.

5. If the pump is going to be idle for a period of time, follow the cleaning instructions.

Do not allow the pump to freeze, which may cause cracking or distortion and
destroy the pump.

6. A clogged or dirty intake screen or filter will greatly reduce performance. If the

pump is used on a dirty surface, raise it slightly to reduce the amount of debris
contacting the intake.

7. Do not let the pump run when not submerged in water. Doing so may damage the

pump. Always submerge the pump before plugging it into the electrical outlet.
Occasionally, due to air in the pump and tube, water will not pump. To initiate
water flow, pull the pump out of the water and insert the plug into the electrical
outlet several times.

ELECTRICAL CONNECTIONS (W

ARNING!)

1.

This pump is supplied with a grounding conductor and a grounding type 
attachment plug. To reduce risk of electric shock, connect only to a properly

grounded outlet.

2. Do not remove the grounding pin from the plug.

3. Do not connect to any voltage other than that shown on the pump.

4. Do not pump flammable liquids.

5. Do not use with water above 86°F (30°C).

MAINTENANCE INSTRUCTIONS:

MONTHL

Y MAINTENANCE WILL INCREASE THE LIFE OF THE PUMP. BEFORE 

SERVICING THE PUMP, PLEASE FOLLOW THESE BASIC RULES:

1.

Always disconnect from electrical outlet before handling the pump.

2. Do not let the pump run dry.

3. Do not lift the pump by the power cord.

4. Operate in clean water only.

5. Operate pump completely submerged for proper cooling.

W

ARRANTY:

The QEP 60095 water pump is war

ranted for 90 days from the date of purchase

against defects in workmanship or materials. Proof of purchase must accompany the
pump when submitting it for repair. The pump must be sent postage paid. This 
warranty is only valid for the replacement or repair of defective parts and is considered
void if the pump is improperly used or handled, or if damages are caused by the 
negligence on the part of the buyer. Any defective pump returned under warranty will be
fully inspected by Q.E.P. to determine cause of the failure before warranty is approved.

Summary of Contents for STK 60095

Page 1: ...STK 60095 Submersible Tile Saw Water Pump OWNER S MANUAL Pompe À Eau Pour Scie À Tuile Immergée MANUEL D UTILISATION Bomba De Agua Sumergible Para Sierra De Baldosas MANUAL DE OPERACIÓN ...

Page 2: ... run when not submerged in water Doing so may damage the pump Always submerge the pump before plugging it into the electrical outlet Occasionally due to air in the pump and tube water will not pump To initiate water flow pull the pump out of the water and insert the plug into the electrical outlet several times ELECTRICAL CONNECTIONS WARNING 1 This pump is supplied with a grounding conductor and a...

Page 3: ...4 Remove the pump inlet to access the impeller area Turn the rotor to ensure it is not broken or jammed 5 Make sure the electrical cord loops below the electrical outlet to form a drip loop This will prevent water from running down the cord into the electrical outlet See illustration for proper assembly and disassembly of your QEP 60095 water pump SEAL RING Flow Rate By Adjusted Flow By Height Per...

Page 4: ...s laisser la pompe fonctionner lorsqu elle n est pas submergée dans l eau Cela risque de l endommager Toujours submerger la pompe avant de la brancher dans la prise de courant Parfois à cause d une poche d air qui se trouve dans la pompe et le tuyau l eau n est pas pompée Pour initier le débit d eau retirer la pompe de l eau et insérer la fiche dans la prise de courant plusieurs fois CONNEXIONS ÉL...

Page 5: ...te accumulation peut être rincée avec de l eau 3 Vérifier l admission pour s assurer qu elle ne soit pas colmatée de débris Filtre de rinçage 4 Retirer l admission de la pompe pour accéder à la zone de la turbine Tourner le rotor pour s assurer qu il ne soit pas brisé ou bloqué 5 S assurer que les boucles du cordon d alimentation sous la prise de courant forment une boucle d égouttement Cela empêc...

Page 6: ... toma 7 No deje la bomba en funcionamiento cuando no esté sumergida en agua podría dañar la bomba Siempre sumerja la bomba antes de conectarla en una salida eléctrica Ocasionalmente debido a la existencia de aire en la bomba y el tubo el agua no bombeará Para iniciar el flujo del agua extraiga la bomba del agua e inserte el enchufe en la salida eléctrica varias veces CONEXIONES ELÉCTRICAS ADVERTEN...

Page 7: ...r posible obstrucción Puede extraer la acumulación de residuos con agua 3 Revise la toma para asegurarse de que no esté obstruida con residuos Enjuague el filtro 4 Quite la admisión de la bomba para acceder al área del impulsor Gire el rotor para verificar que no esté roto o atorado 5 Verifique que el cable eléctrico quede entrelazado debajo de la salida eléctrica formando un bucle para goteos Ell...

Page 8: ...Fits QEP Tile Saws Sea Adapta a Sierras de QEP para Baldosas Convient aux Scies à Carreaux QEP Q E P Co Inc Boca Raton FL 33487 800 777 8665 www qep com T162 STK 60010 STK 60060 STK 60024 ...

Reviews: