background image

27

EN

POWER SUPPLY

B

INSERT 3 X AAA NIMH BATTERIES

Ensure correct polarity when inserting the batteries.

CHARGE THE BATTERIES

Open the cover of the USB plug 

(bottom of the instrument)

 and charge 

the batteries via the USB connection. For this use a standard USB charger, 

i. e. from a smart phone. When the charging process is completed close 

the USB plug.

Alternatively the instrument can be operated with standard AAA Alkaline 

batteries.

FEATURES

C

1.  Measuring key (press briefly: single measurement /  

press long: continuous measurement)

2.  ON / OFF key 

press briefly = back 

press long = ON / OFF

3.  Laser warning symbol

4.  Touch screen

5.  Camera function 

activation / zoom in and out

6.  Battery case 

7.  Tripod thread

Summary of Contents for GeoDist 100

Page 1: ...www geo fennel com EN GeoDist 100 USER MANUAL ...

Page 2: ...al carefully and keep it in a convenient place for future reference This manual contains important safety information that should be read and understood before use Technical specification and design are subject to chance without notifi cation geo FENNEL Precision by tradition EN Contents 1 Supplied with A 2 Power supply B 3 Features C 4 Operation D 5 Safety notes E ...

Page 3: ...ring range 0 2 100 m Measuring accuracy 2 mm Tilt measurement accuracy 0 3 Laser class 2 red Power supply NiMH Temperature range 10 C 40 C Measuring units m ft in ft in Dust water protection IP 65 Dimensions 115 x 50 x 26 mm Weight with batteries 148 g May be shorter under unfavourable conditions Typical accuracy may increase under unfavourable conditions ...

Page 4: ... point partial height Indirect measurement 1 Indirect measurement 2 Measurement point to point Trapezoid measurement 1 Trapezoid measurement 2 Triangle area calculation Circle area calculation Cylindrical volume Stake out function Offset function Time delayed measurement Memory Data export via USB GeoDist Connect App iOS and Android Trouble shooting FEATURES P 30 P 31 P 32 P 33 P 34 P 35 P 36 P 37...

Page 5: ...a standard USB charger i e from a smart phone When the charging process is completed close the USB plug Alternatively the instrument can be operated with standard AAA Alkaline batteries FEATURES C 1 Measuring key press briefly single measurement press long continuous measurement 2 ON OFF key press briefly back press long ON OFF 3 Laser warning symbol 4 Touch screen 5 Camera function activation zoo...

Page 6: ...ll appear DISPLAY INDICATION TOUCH SCREEN The instrument is equipped with a touch screen Coming from the start screen slide right selection of the measuring modes pict 1 slide left add subtract pict 2 slide down menu pict 3 4 The menu keys are operated with a finger tip Abb 1 2 Abb 3 4 ...

Page 7: ...ey off slide scroll delete arrow buttons select digit set value measurement starts after 5 seconds 1 Bluetooth function 2 Measuring unit 3 Measuring reference 4 Digital vial 5 Rotate the display available in measuring mode 6 View memory 7 Define off set 8 Time delayed measurement Quit the menu ...

Page 8: ... Numerical slope indication Preferably keep the instrument at 0 Optical support Green bar move the bar exactly between the marks Measuring reference Bluetooth Angle display Battery status indication Measuring mode indication Value measured Digital level display Measuring mode 1 Value measured Volume 2 Value measured 3 Value measured DISPLAY INDICATION IN MEASURING MODE ...

Page 9: ...ys active In all measuring modes except single and continuous measurement the red line shows which parameter will be measured next The green L shows the parameter to be determined CAMERA FUNCTION camera function Press to activate the camera function in all measuring modes in case the target is not visible with the eye especially in case of outdoor measurements zoom in out Start the measurement wit...

Page 10: ... and forth over the selected target point Press to stop the continuous measurement Display indication maximum minimum and the last measured value MEASURING REFERENCE Press to select the requested measuring reference FRONT TRIPOD REAR ADDITION SUBTRACTION In the modes distance measurement area and volume calculation slide left and select or to execute the requested task ...

Page 11: ...for the first distance Press for the second distance Display indication line 3 area Press for a new area calculation press the OFF button to quit this mode VOLUME CALCULATION Select and press Press for the first distance Press for the second distance Press for the third distance Display indication line 4 volume Press for a new volume calculation press the OFF button to quit this mode ...

Page 12: ...icator 0 All measurements must be vertically in line without lateral deviation Use a tripod to increase the measuring accuracy PYTHAGORAS 3 POINT Select and press Press for the inclined distance top Press for the horizontal distance Press for the inclined distance bottom Display indication line 4 height PYTHAGORAS 2 POINT Select and press Press for the inclined distance Press for the horizontal di...

Page 13: ...EASUREMENTS VIA INCLINATION WITH HIGH ACCURACY Where direct measurements to the target are not possible e g on glass facades without measurement reflection or when the measurement object is obscured Measure partial distances missing distances are calculated by the device Here a general note All measurements must be vertically in line without lateral deviation Use a tripod to increase the accuracy ...

Page 14: ...ication line 1 angle Display indication line 2 inclined distance top Display indication line 3 inclined distance bottom Display indication line 4 height INDIRECT MEASUREMENT 1 Select and press Press Display indication line 1 angle Display indication line 2 inclined distance top Display indication line 3 height Display indication line 4 horizontal distance ...

Page 15: ...distance to the first measuring point Display indication line 3 distance to the second measuring point Display indication line 4 distance between both measuring points In order to increase the measuring accuracy especially for long distances use a tripod TRAPEZOID MEASUREMENT 1 Select and press Press for the first distance Press for the second distance Press for the third distance Display indicati...

Page 16: ...ss for the first distance Press for the second distance Press for the third distance Display indication line 4 triangle area TRAPEZOID MEASUREMENT 2 Select and press Press for the first distance Press for the second distance Display indication line 1 angle diagonal horizontal Display indication line 2 altitude Display indication line 3 length of the hypotenuse Display indication line 4 length of t...

Page 17: ... Display indication line 3 cylinder area Display indication line 4 cylinder volume STAKE OUT FUNCTION Select and press switch the digits with the arrow buttons define the requested offset with start with The red arrow shows in which direction the unit must be moved to reach the distance required When approaching the target an accoustic signal will sound ...

Page 18: ...call OFFSET FUNCTION Select and press switch the digits with the arrow buttons define the requested offset with confirm with The activation of the offset function will be displayed permanently by this symbol ATTENTION The offset function is permanently active even after powering off on of the unit This function must be de activated after finishing the measuring task ...

Page 19: ...ing of the measurements photograph and dimension measurement situations dimension imported photos create and dimension sketches create measurement data lists Data export e g by e mail for further processing You will find the GeoDist CONNECT APP for smartphones tablets iOS units from iOS 7 0 in the App Store Android units from Android 4 3 in Google Play Compatible with Bluetooth 4 0 or higher You w...

Page 20: ... 220 Battery weak Charge the battery 255 Signal too weak or measuring time too long Change the target surface 256 Signal too strong Change the target surface 261 Out of measuring range Select the measuring distance within the range 500 Hardware error Power on off the device several times If the error code still appears contact your dealer ...

Page 21: ...e wait some minutes before carrying out measurements CARE AND CLEANING Handle measuring instruments with care Clean with soft cloth only after any use If necessary damp the cloth with some water If the instrument is wet clean and dry it carefully Pack it up only if it is perfectly dry Transport in original container case only ELECTROMAGNETIC ACCEPTABILITY EMC It cannot be completely excluded that ...

Page 22: ...ption of business etc caused by using the product or an unusable product 5 The manufacturer or its representatives assumes no responsibility for any damage and loss of profits caused by usage other than explained in the user manual 6 The manufacturer or its representatives assumes no responsibility for damage caused by wrong movement or action due to connecting with other products WARRANTY This pr...

Page 23: ...labels or safety instructions Keep the instrument away from children Do not use the instrument in explosive environment The user manual must always be kept with the instrument LASER CLASSIFICATION The instrument is a laser class 2 laser product according to DIN IEC 60825 1 2014 It is allowed to use the unit without further safety precau tions The eye protection is normally secured by aversion resp...

Page 24: ...5 Baunatal Tel 49 561 49 21 45 Fax 49 561 49 72 34 info geo fennel de www geo fennel de Technische Änderungen vorbehalten All instruments subject to technical changes Sous réserve de modifications techniques Precision by tradition 03 2021 ...

Reviews: