27
EN
TILT FUNCTION
Powering on the laser the TILT function will be activated automatically. „TILT“ is flashing during the
activation procedure. When the activation is completed (after 90 sec approx.) „TILT“ is indicated perma-
nently.
Press button
to switch this function on/off.
When the TILT function is active:
If the laser is disturbed, the rotation stopps and the laser beam and „TILT“ will flash. The laser will not
re-level automatically.
If required self-levelling procedure can be reactivated with button
.
This instrument has three TILT status:
Activation
=„TILT“ flashes slowly during the activation, the instrument in not yet ready for use
Function active
= TILT“ is indicated permanently
TILT alarm
= „TILT“ is flashing quickly and the rotation stopps
VIBRATION-WIND-SECURITY
(VWS FUNCTION)
Press this button to activate the VWS mode. The VWS function automatically activates the TILT function.
This function allows continuous operation during periods of vibration and wind. If a significant movement
occurs the laser stops rotating and the TILT LED starts flashing. Press the VWS button to cancel. Press
the VWS button again to re-activate.
SLEEP / MANUAL FUNCTION
Press this button once enter into the SLEEP mode. The instrument and the remote control are now in
standby mode. All values set will be stored. After restart the instrument will work with the same vales as
before.
Note:
After 60 min. in standby function the laser automatically switches off.
Press the button again to re-active the instrument and the remote control.
Press the button long to enter into the MANUAL mode.
Now the laser can be used in slope postion as the instrument does not power off or re-levels automatical-
ly.