QED Sample Pro 3 Inch Instruction Manual Download Page 7

4

Assembly

Use 

Figure 2

, (Page 3) to identify main pump components and 

Figure 3

, (below) to

identify O-ring locations.  Detailed exploded view drawing of the upper end of the

pump are shown on pages 7 and 8.  

1.

See 

Figure 3

 (below) to identify locations where O-rings and seals are to be installed 

and install all O-rings and seals.

2.

 Connect the bladder to the pump head. The PE bladder pushes onto the pump head

 barb until the bladder fully covers the barb.   

3.

Attach the pump head to the body by engaging the bayonet dimples into the grooves

and twisting them together until the engagement snap is felt and head and body

alignment marks line up.  

4.

With the pump on its side, insert the inlet check ball (same as the discharge check 

ball) into the side of the pump head, then press in the inlet valve seat by pushing

with your thumb. Pre-wetting the parts with distilled water is recommended to aid

assembly   

.

5.

With the pump vertical, insert the discharge check ball into the top of the pump

head, place the discharge ball stop into place above the check ball, using the sup-

plied needle nose pliers, see 

Figure 5

, (Page 6). 

6.

 For the push-in tubing fittings, place the thin metal lock disk in the "TOP" up posi-

 tion on the top of the pump head, with the lock disk edge slots lined up with the

 posts on the pump head. Then place the thick, upper plate on top of the lock disk,

 again with the slots and posts lined up. Finally, twist the pump cap onto the pump

 head until the engagement snap is felt and the hole in the side of the pump cap lines

 with the inlet port. Cover and body alignment marks will line up.    

Discharge Sea

l

1/4 Tube-38677

Ball 38471

Bal

l

38471

Ball Stop 38438EP

Air Tube Seal 38676

Inlet O-Ring 38470

Inlet

38439EP

H

e

ad

O-R in

g

s

3517

2

Bla

d

de

r

O-Ring

38470

Head 38437EP

Figure 3

Assembly

Summary of Contents for Sample Pro 3 Inch

Page 1: ...o 3 4 Portable MicroPurge Pump Part No 95192 3 9 04 Sample Portable Pumps MicroPurgeR Manual Instruction P O Box 3726 Ann Arbor MI 48106 3726 USA 1 800 624 2026 Fax 734 995 1170 info qedenv com www qe...

Page 2: ......

Page 3: ...lenose Pliers for Check Ball Stop Assembly Disassembly Figure 6 PumpTubing FittingAssembly Figure 7 Pump Head Assembly Figure 4 TubingAttachment T ool 1 2 8 5 Figure 3 O Ring Replacement 4 3 Figure 1...

Page 4: ...assembly without tools and quick change disposable bladders The Portable MicroPurge Pump is com pact and can pump from a 5 gallon bucket The pump is operated by compressed gas and a bladder pump contr...

Page 5: ...the top of the pump and tubing for use of a cable when preferred The connection eye is threaded into the top plate of the pump and can easily be removed or reinstalled as desired The push in fittings...

Page 6: ...Tube x 1 8 Tube Plate 1 4 Tube x 1 8 Tube O Ring Viton Seal Discharge Seal Air Supply O Ring Viton Ball Teflon Ball Stop 9 1 38438EP 10 1 38677 38676 QTY Part No Description 1 3 4 11 12 13 1 1 1 1 1...

Page 7: ...eat by pushing with your thumb Pre wetting the parts with distilled water is recommended to aid assembly 5 With the pump vertical insert the discharge check ball into the top of the pump head place th...

Page 8: ...turing the bladder Attaching Tubing A tubing insertion tool is provided to make the small diameter tubing used on this pump easier to grip and push into the pump The tool is shown in Figure 4 1 Cut bo...

Page 9: ...Disassembly Needlenose pliers are provided to make handling of certain smaller parts easier to handle during cleaning assembly and disassembly Figure 5 demonstrates placement of the check ball stop i...

Page 10: ...2 Cover Grab Plate 1 4 Tube x 1 8 Tube O Ring Viton Ball Teflon Ball Stop Seal Air Supply Seal Discharge Plate 9 1 1 38438EP QTY Part No Description 7 2 5 11 9 7 8 13 12 14 14 13 12 11 1 38833 38435 3...

Page 11: ...1 6 6 7 3 11 Item No 1 3 6 7 1 1 2 1 38437EP 38439EP 38470 38471 Head Inlet O Ring Viton Ball Teflon QTY Part No Description 8 Figure 7 Figure 7...

Page 12: ...this o ring could cause the water sample to be contaminated by pump drive air 3 Install the new bladder by pushing it onto the pump head barb until the bladder fully covers the barb making sure the ba...

Page 13: ...d tube end and or use of other brands of tubing may significantly reduce pull out strength and cause loss of pump in the well 10 Specifications Body 303stainlesssteel Inlet DischargeHousing 303Stainle...

Page 14: ...ach of said warranty shall be as follows if and only if Q E D is notified in writing within applicable warranty period of the existence of any such defect in the said products and Q E D upon examinati...

Page 15: ...ified by persons other than Q E D s service personnel unless such repair by others is made with the written consent of Q E D If any product covered hereby is actually defective within the terms of thi...

Page 16: ...P O Box 3726 Ann Arbor MI 48106 3726 USA 1 800 624 2026 Fax 734 995 1170 info qedenv com www qedenv com...

Reviews: