14
Product Overview
3.5 Specifications
GENERAL PRODUCT INFORMATION
Dimensions Inverter Module /
Battery Module (W × H × D)
[mm]
460 × 700 × 221, 238 (From Wall)
Weight Inverter Module / Battery Module
[kg]
33.9 / 61.1
Operating Temperature Range
[°C]
Q.VOLT: −20 to 60 / Q.SAVE: −10 to 45
Relative Humidity
[%]
4 to 100 (Condensing)
Protection Degree / Class
IP65
Mounting
Wall-Mounted or Floor-Mounted Options
Max. Operation Altitude
[m]
2,000
Cooling Method
Natural air cooling
Product Warranty / Performance Warranty
15 / 15 years
Noise Emissions
≤ 40 dB (A) @ 1 m
Over Voltage Category
OVC II (DC) / OVC III (AC)
Communications
LAN, RS485, CAN, Wi-Fi (optional), LTE (optional)
Remote Monitoring
Web, Mobile & App
Software Update
Online update
Energy Management System
Integrated
Country of Manufacturer
Republic of Korea
GRID DATA (AC)
Max. Apparent Power / Rated Output Power
[kVA / kW]
5 / 5
Nominal Voltage
/
Range
[V]
230 / 180 to 260
Nominal Grid Frequency
/
Range
[Hz]
50, 60 / −5 Hz to +5 Hz
Feed-in Phase / Connection Phase
Single / Single
Nominal Current / Max. Current /
Max. Over-Current Protection
[A]
21.7 / 25 / 30
Power Factor Range
0.8 lagging to 0.8 leading
Total Harmonic Distortion
[%]
≤ 5
BACKUP POWER OUTPUT (ALTERNATING CURRENT)
Connection Phase
Single
Rated Apparent Power /
Rated Power (Only Battery)
[kVA / kW]
3.3 to 4.5 / 3.3 to 4.5 @ 1 Battery Pack,
5 / 5 @ 2, 3 Battery Pack
Rated Voltage
[V]
230
Rated Frequency
[Hz]
50, 60
Switch over Time to Backup Power
less than 0.1 seconds
Overload support
30 sec for 5.0 - 5.5 kVA, 20 sec for 5.5 - 6.0 kVA,
10 sec for 6.0 - 6.5 kVA
@ 2, 3 Battery Pack and Off-grid
* The backup power output of load terminal is not suitable to supply inductive or capacitive load that causes high inrush
current.