Optimizer4D Technical Specifications
25 / 27
Memory options
Pos. Usage
Basic or
optional
Memory
size
Maximum
size (all in all)
Magnetic or SSD
1
Operating system and
storage for measuring data
(bending and straightening)
basic
0,5 TB
0,5 TB
SSD
2
Operating system and
storage for measuring data
(other applications)
basic
128 GB
128 GB
SSD
3
Memory expansion pack #1
optional
additional
1 - 1,5 TB
2 TB
Magnetic and SSD
4
Memory expansion pack #2
optional
additional
2-4 TB
4,5 TB
Magnetic and SSD
5
Memory expansion pack #3
optional
additional
4,5-5,5 TB
6 TB
Magnetic and SSD
Optimizer4D
writes measuring data in
real-time to it‘s harddrives. While using
highest data rate, Optimizer4D saves up
to 25 MB / s to harddrive. This means 1,5
GB / min or 90 GB / h. 1 TB of memory
will be full in roughly 11 hours.
Additionally, Optimizer4D saves results of
measuring (crack / no crack) as
statistics
to a database. It‘s also possible to add
screenshots to this statistics. You‘ll dra-
matically save harddrive space if you keep
just the screenshots and the statistics as
opposed to the complete measuring data.
Basic memory configuration
of Optimi-
zer4D provides 500 GB of SSD memory.
You can freely add as much memory as
you want up to 6 TB in steps of 1 or 1,5 TB.
There are four slots for harddrives availab-
le. Refer to list below for examples.
For
extended needs for storage
, a
external NAS-system is available. This
system stores up to 128 TB (sufficient for
up to 1400 hours of measuring with one
measuring channel).
NAS-system for extended data storage.