background image

CSA REQUIREMENTS

QTM - eLED+DMX

CSA Label

● Suitable for Indoor use

● This power supply must be installed according to the National Electric Code and local codes and ordinances and in accordance with applicable installation 

    code by a person familiar with the construction and operation of the product and the hazards involved.

● Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.

● This power supply is to be installed in a location where it is not likely to be contacted by non-electricians.

● To avoid a hazard to children, account for all parts and destroy all packaging materials.

● 

DMX Shield wire must be grounded 

to Earth Ground at a single point external to Power Supply

7

Model

Input Voltage

 (V)

Frequency

Nominal Output

Voltage (VDC)

Nominal Output 

Wattage (W)

Input Current 

(A)

QTM-eLED-100

QTM-eLED-200

QTM-eLED-300

120-277

120-277

120-277

0.95/0.40

1.90/0.80

2.85/1.20

50/60

50/60

50/60

24

24

24

100

200

300

QTM-eLED-60

QTM-eLED-120

QTM-eLED-180

120-277

120-277

120-277

0.60/0.29

1.20/0.58 

1.80/0.87

50/60

50/60

50/60

12

12

12

60

120

180

Q-Tran, Inc.

Q-TRAN, INC.

MILFORD, CT U.S.A. 

(203) 367-8777 

WWW.Q-TRAN.COM

CLASS:  

3425 - 15

               

3425 - 95

LOW VOLTAGE 

LIGHTING SYSTEM

● Type Ic Recessed, Inherently Protected

   

Type IC ENCASTRE, PROTECTION INHÉRENTE

● For Supply Connections Use 

Wire Rated 

  

For At Least 60 C.

● Not for use with dimmers

    

NE CONVIENT PAS A DES GRADATEURS

● Suitable For Damp Locations

    

CONVIENT AUX EMPLACEMENTS HUMIDES

● 50/60 Cycle
● Class 1 or Class 2

This product must be installed in accordance with the applicable 

installation code by a person familiar with the construction and 

operation of the product and the hazards involved.

CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D'INSTALLATION 
PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET 
SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS.

QTM-eLED

120V-277 

INPUT VOLTAGE

OUTPUT VOLTAGE

24V

12V

CONTROL TYPE

DMX

0-10V

WD

AW

© 2020, Q-Tran Inc.  155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777  -  [email protected]  -  www.q-tran.com

Summary of Contents for QTM-eLED+DMX

Page 1: ...AGE LIGHTING SYSTEM QTM eLED DMX COMPLIANT Wear rubber shoes and work on a sturdy wooden or fiberglass ladder This power supply must be installed according to the National Electric Code and local codes and ordinances This power supply is to be installed and serviced only by an licensed electricians This power supply is to be installed so that it is not likely to be contacted by people To avoid a h...

Page 2: ...ons Suitable for surface or recessed mounting use Primary Voltage Universal 120 277V Wide operating temperature range 4 degF to 122 degF Fits up to 3 100W 24 VDC driver s and DMX decoder module s DMX dimming down to 0 Driver has Class A sound rating Class 2 Output 5 year warranty CSA 239924 Low Voltage Lighting Systems CSA Class 3425 15 and Class 3425 95 CSA Standard C22 2 No 250 0 08 Luminaires A...

Page 3: ...hese connectors when the driver is used in a DMX network For DMX in connect the network cable s DMX DMX and DMX shielding wire the orange white orange and brown wire in a CAT5 cable to the DMX in DMX in and DMX in shield connector respectively For LedSync out connect the network cable s DMX DMX and DMX shielding wire to the LedSync out LedSync out and LedSync shield connector respectively DMX Shie...

Page 4: ...SED MOUNT Plenum Door Required Horizontal Vertical SURFACE SPACING SURFACE STACKING ROD SUSPENSION 9 5 O C 16 O C 19 O C 9 5 O C 9 5 O C More Units can be stacked More Units can be stacked More Units can be stacked NOTE Rods not included RECESSED SURFACE ROD SUSPENSION Horizontal ROD SUSPENSION Vertical VERTICAL QTM eLED DMX Housing Mounting Options 3 2020 Q Tran Inc 155 Hill St Milford CT 06460 A...

Page 5: ...injury or death Disconnect power before servicing or installing CAUTION The device may only be connected and installed by a qualified electrician All applicable regulations legislation and building codes must be observed Incorrect installation of the device can cause irreparable damage to the device and the connected LEDs DMX Shield must be grounded to Earth Ground at a single point external to po...

Page 6: ...UE M HUE White WHIT M M Intensity 0 255 INT display off 0 1535 0 255 M M M 1 512 Network resolution DMX address 8 BT 16 BT display off ADDR DMX RES NETW M Interpolation OFF VID COLR WHIT GLOW INTERPOL Other features Visual test run Locking the configuration Reset to factory defaults M display off TEST Test R 1 sec G 1 sec B 1 sec W 1 sec RGBW 1 sec R 1 sec G 1 sec B 1 sec W 1 sec RGBW 1 sec displa...

Page 7: ...Shield DMX DMX M LED Blue Blue White White Green Green Red Red Black 24V W B G R 24V NEU GND HOT GND HOT NEU A B C 6 for interior QTM eLED DMX QTM eLED DMX Wiring Installation 2020 Q Tran Inc 155 Hill St Milford CT 06460 All rights reserved 203 367 8777 sales q tran com www q tran com W B G R 24 W B G R 24 W B G R 24 DMX IN DMXOUT A B C LED LED LED GND DMX DMX Red Blue Green To next power supply ...

Page 8: ...24 24 24 100 200 300 QTM eLED 60 QTM eLED 120 QTM eLED 180 120 277 120 277 120 277 0 60 0 29 1 20 0 58 1 80 0 87 50 60 50 60 50 60 12 12 12 60 120 180 Q Tran Inc Q TRAN INC MILFORD CT U S A 203 367 8777 WWW Q TRAN COM CLASS 3425 15 3425 95 LOW VOLTAGE LIGHTING SYSTEM Type Ic Recessed Inherently Protected Type IC ENCASTRE PROTECTION INHÉRENTE For Supply Connections Use Wire Rated For At Least 60 C ...

Reviews: