background image

© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com 

Specification subject to change. Rev-06-15-23

COMPLIANT

QTM-eLED+DALI-DT6-AN

   

LED POWER SUPPLY 100W–200W

Protections

• 

Short Circuit Protection (SCP)

• 

Over Voltage Protection (OVP)

• 

Over Current Protection (OCP)

• 

Class 2 Output

Compliance

• 

EMI Spec  : FCC 47 Part 15 

: EN61000-3-2

• 

CSA Certified  : UL-2108 

: UL-8750 
: CSA C22.2 No 250.0-08 
: CSA C22.2 No 250.13-14

Input

24VDC

Input Voltage (Vrms)

120

230

277

Input Current, max (Arms)

0.98

0.51

0.43

Inrush Current, max

*

 (Apk)

---

20

---

Input Frequency (Hz)

50/60

Input Power (W)

117

Environmental

Min

Nom

Max

THD (%)

---

---

20

PF (%)

0.90

---

---

Case Temp (ºC)

---

---

90

*

- 200us event

0

20

40

60

80

100

120

25

30

35

40

45

50

55

60

65

70

75

80

85

90

Li

fe Time (kHrs)

Case Temperature (ºC)

Life Time vs. Case Temperature

Output Current (A)

120Vrms

277Vrms

23.4

23.5

23.6

23.7

23.8

23.9

24

24.1

24.2

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

Output Voltage (V)

Vout vs. Iout, 24VDC 

20

40

60

80

100

% Rated Load

120Vrms

277Vrms

100

90

80

70

60

50

0

E

ciency (%)

Efficiency, 24VDC

Output

SW

DW

Output Voltage, nom (V)

24

24

Output Current (Amax)  

per channel

4

4

Output Power (Wmax)  

per decoder

100

100

Specifications 

(per 100W circuit)

Summary of Contents for QTM-eLED+DALI-DT6-AN

Page 1: ...ron Athena Wireless Nodes which streamlines installation time and allows for simple programming using the Athena iOS or Android app The power supplies and decoders are prewired together with terminal...

Page 2: ...IN LED groups D1 D2 D1 D2 DALI Signal in out Housing 18 gauge welded steel enclosure 14 5 W x 8 00 H x 4 00 D Door 15 5 W x 9 00 H Knockouts 25 Built in support bracket incorporated to secure housing...

Page 3: ...0 277 Input Current max Arms 0 98 0 51 0 43 Inrush Current max Apk 20 Input Frequency Hz 50 60 Input Power W 117 Environmental Min Nom Max THD 20 PF 0 90 Case Temp C 90 200us event 0 20 40 60 80 100 1...

Page 4: ...ely Lutron Athena control system required By others LED groups Indicates the location of the connectors for your LED groups The default group addressing can be changed over the 2 button user interface...

Page 5: ...um Door Required Horizontal Vertical SURFACE SPACING SURFACE STACKING ROD SUSPENSION 9 5 O C 16 O C 19 O C 9 5 O C 9 5 O C More Units can be stacked More Units can be stacked More Units can be stacked...

Page 6: ...d work on a sturdy wooden or fiberglass ladder This power supply must be installed according to the National Electric Code and local codes and ordinances This power supply is to be installed and servi...

Page 7: ...ired Horizontal Vertical SURFACE SPACING SURFACE STACKING ROD SUSPENSION 9 5 O C 16 O C 19 O C 9 5 O C 9 5 O C More Units can be stacked More Units can be stacked More Units can be stacked NOTE Rods n...

Page 8: ...e observed Incorrect installation of the device can cause irreparable damage to the device and the connected LEDs V V V V 1 2 3 4 24VDC IN LED groups LED Primary Wiring Secondary Wiring NEU GND HOT LE...

Page 9: ...nd hold either button Use the buttons to set address 1 2 Set Address 5 sec 1 Locking the configuration Confirm 1 2 Press and hold either button 5 sec 2 Reset to factory defaults Reset 1 2 1 2 Set Addr...

Page 10: ...DT6 AN V V V V 1 2 3 4 24VDC IN LED groups D1 D2 D1 D2 DALI Signal in out V V V V 24VDC IN LED groups D1 D2 D1 D2 DALI Signal in out 1 2 3 4 OUTPUT LOAD SECONDARY PRIMARY DA DA 24V 24V for interior G...

Page 11: ...National Electric Code and local codes and ordinances and in accordance with applicable installation code by a person familiar with the construction and operation of the product and the hazards involv...