6
Connections and Callouts
SPA-Qf 60x2 Front Panel
1
2 3
4 5
1.
ID Button
– Press to identify this product in Q-SYS Designer Software. (All front panel LEDs will flash.)
2.
Limiter / Protect LEDs
– The channel limiter is activated on input or output (orange) or in protect mode (red). Protect Mode can
be caused by shorts, open circuits, and over-temperature conditions.
3.
Input Signal LEDs
– A signal exceeding -50 dBFS is present for the channel (blue). If the amplifier is in Bridge or Parallel mode,
only the odd channel LED will illuminate.
4.
Power LED
– The amplifier is on and operational (solid blue) or in standby (slow flashing blue; all amplifier channels are in
standby).
5.
Fault LED
– The amplifier is unable to pass audio or is malfunctioning or not properly configured (fast flashing orange). This could
be caused by broken audio streams, amplifier fault, or loudspeaker short circuit. Refer to the Status component in Q-SYS Designer
Software for fault details.
SPA-Qf 60x2 Rear Panel
1
2
4
5
6
3
1.
Output Channels A and B
– For connection to loudspeakers. Uses the 4-position green Euro connector.
2.
GPIO
– Pins 1-4 are user-configurable and bi-directional; one 3.3V 100mA power pin; one ground pin. Uses the 6-position black
Euro connector.
3.
Flex Channels 1 and 2
– User-configurable audio channels (mic/line input with optional phantom power or line output),
balanced or unbalanced. Each channel uses the 2-position blue Euro connector.
4.
Reset Button
– Use the Reset button to restore default network settings and clear the amplifier's password and log file. Before
attempting a reset, refer to the
5.
LAN
– RJ45, 1 Gigabit connection to Q-LAN network.
6.
AC Power
– 100-240V~ 50/60 Hz