58
59
PICTURE 4-32
PICTURE 4-33
4.6 ADVANCED
The settings in this menu cover user accounts, hard disk management, video display, and
system maintenance.
CAUTION!
Reformatting the hard drive will erase all recorded events.
HDD MANAGE
This displays some of the same information found in the
HDD Info
window in the
Info
menu
(see
Section 4.2
) but this window allows you to make additional settings.
The drive name and status is displayed.
The status indicators are:
Clicking on
Alarm Set
opens the
Abnormality
window which is covered immediately
following this section.
Alarm Release
– this turns off any disk alarm that may be occurring.
You can set the hard drive to four states:
O
Drive is operating normally.
X
Indicates an error
-
Hard drive not installed
?
Hard drive is damaged
Read/Write
Normal operation. The device records (writes) files to disk and plays (reads)
them.
Read Only
No more files can be recorded onto the drive, but existing files can be viewed.
Format
Reformats the hard drive.
Recover
If you are having problems with the hard drive, including corrupted files,
selecting Recover causes the drive to re-set, but does not erase its contents.
No changes will take place unless the Execute button is pressed once you’ve made your
selection. The drive’s status will be displayed next to the Type heading below the pull-downs.
If you make changes and press
Execute
, the NVR will restart once you press
OK
to exit. You
cannot right-click out of the menu.
Manual Add
If you have changed the default settings of any remote device which you wish to use with
your NVR, you will need to use the
Manual Add
button at the bottom of the window to
add this device to the list of connected devices. This applies to cameras and DVRs which
were previously connected but later removed from the list of connected items. Items being
accessed from outside your local network will also need to be added using this button.
Within the
Manual Add
window, some information may already be displayed but it may not be
correct for the device you are intending to connect.
PICTURE 4-31
REMOTE DEVICE
Filter
None
Delete
Manual Add
IP Search
Add
OK
Cancel
4
IP Address
Port
Device ID
Manufacturer Type
1
10.1.1.65
Port 1 YZC2OC061966
Private
IPC
2
10.1.1.67
Port 2
YZCAU192012
Private
IPC
3
10.1.1.68
Port 4 TC2FW25600095
Private
IPC
4
196.219.8.50 4000
Private
channel Edit Delete Status IP Address
Port
Device ID
1
196.610.6.46 37777
2
10.1.1.67
Port 2
YZCAU192012
3
10.1.1.68
Port 4
TC2FW25600095
4
10.1.1.65
Port 1
YZC2OC061966
Device Added
Manual Add
Channel
Manufacturer
IP Address
TCP Port
User
Password
Remote Channel
Decoder Buffer
1
Private
IPC.myq-see.com
37777
admin
1
280
Save
Cancel
Channel
- Select an available channel to
which you want to assign this device.
Manufacturer
- You can leave this
unchanged.
IP Address
- If this device is connected to
the same network as the NVR, the IP address
will appear in upper portion of the
Remote
Device
window along with the device name.
If this device is located outside of your local
network, you will need to determine the
IP address locally to the device (see the
Remote Monitoring Guide
).
TCP Port
- The default is 3777. Devices
being accessed over the Internet may
be using a different port. You will have
determined this during setup.
User/Password
- Enter the user name and password you set for the device. The default user
name and password for QC-Series IP cameras are
admin
and
admin
. For other brands,
please consult your product manual.
Remote Channel
- Leave this unchanged.
Decoder Buffer
- Ranges from 80 to 480, but it is better to leave it at the default value of 280.