41
Operation and Maintenance Manual
QTS Series Twin Screw Positive Displacement Pump
QTS-M04
After CIP cleaning an additional sterilization in place process (SIP) may be required when highly
sensitive products are handled, inactivating any micro-organisms which might be still present in
the pump. The sterilization can be carried out by means of chemicals, hot water or steam. In the
dairy industry the sterilization temperature is approximately 145 °C (293 °F). Contact Q-Pumps in
case of temperatures above 100 ºC (212 ºF).
Because of QTS pumps are capable to supply the CIP fluid running at high speed please provide
system information for selecting the right values of rpm for CIP supply.
Normally when ordered, the QTS Pumps are selected for both, the application and for the CIP supply.
Rpm speed table for each pump model, for turbulent flow to achieve the CIP process in different pipes:
Pipe Diameter
1.5
2.0
2.5
3.0
4.0
6.0
QTS102 - 1.5 m/s
1146
2100
3372
QTS102 - 3.0 m/s
2291
QTS103 - 1.5 m/s
1707
3133
QTS103 - 3.0 m/s
3414
QTS202 - 1.5 m/s
799
1281
1418
QTS202 - 3.0 m/s
1598
2562
QTS203 - 1.5 m/s
1188
1906
2149
QTS203 - 3.0 m/s
2375
QTS302 - 1.5 m/s
532
780
1418
QTS302 - 3.0 m/s
1064
1562
QTS303 - 1.5 m/s
807
1183
2149
QTS303 - 3.0 m/s
1612
2370
For more information please contact Q-Pumps.