19
Operation and Maintenance Manual
QTS Series Twin Screw Positive Displacement Pump
QTS-M04
Mechanical Seals Replacement
1. Here is a description of the procedures for inspection and replacement of the mechanical
seals. Every pump has two mechanical seals.
12J
12H
12G
12F
12E
12D
12C
12B
12A
12J
12H
12G
12F
12E
12D
12C
12B
12A
2. Single mechanical seal kit: it contains
components
12A
to
12J
.
3. Double mechanical seal kit: It contains all
components of the single mechanical seal
plus components
12K
to
12T
; in this case the
stainless steel seal housing (
12J
) is replaced
by the seal housing (
12L
) which is already
included on the double mechanical seal kit.
4. The mechanical seal should be installed
using your hands only. No special tools
are required unless it is indicated. You may
use a hook to take out the O-rings from
their grooves. Be careful not to scratch
the seal faces.
12F
12N
12A
12R
12T
12S
12Q
12P
12M
12L
12K
12H
12G
12E
12D
12C
12B
12F
12N
12A
12R
12T
12S
12Q
12P
12M
12L
12K
12H
12G
12E
12D
12C
12B
5. Look for defects on the sealing surfaces such as scratches or wear. If a replacement is necessary,
it is recommended to change all components to ensure proper operation. If an O-rings is deformed
or damaged it is recommended also to replace the entire set of O-rings.
M
A
INTE
N
A
N
C
E