Symptoms

Potential Cause(s):

Recommendation(s):

Pump Cycles 

Running Sluggish 

/ Stalling, Flow 

Unsatisfactory 

(cont.)

Air supply pressure or volume 

exceeds system hd.

Decrease inlet air (press. and vol.) to the pump. Pump is cavitating the 

fluid by fast cycling.

Undersized suction line.

Meet or exceed pump connections.

Restrictive or undersized air line. Install a larger air line and connection.
Suction side air leakage or air in 

product.

Visually inspect all suction-side gaskets and pipe connections.

Suction line is blocked.

Remove or flush obstruction. Check and clear all suction screens or 

strainers.

Pumped fluid in air exhaust 

muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose 

diaphragm plate assembly.

Check valve obstructed.

Disassemble the wet end of the pump and manually dislodge 

obstruction in the check valve pocket.

Check valve and/or seat is worn 

or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if 

necessary.

Entrained air or vapor lock in 

chamber(s).

Purge chambers through tapped chamber vent plugs. Purging the 

chambers of air can be dangerous.

Product Leaking 

Through Exhaust

Diaphragm failure, or diaphragm 

plates loose.

Replace diaphragms, check for damage and ensure diaphragm plates 

are tight.

Diaphragm stretched around 

center hole or bolt holes.

Check for excessive inlet pressure or air pressure. Consult Chemical 

Resistance Chart for compatibility with products, cleaners, temperature 

limitations and lubrication.

Premature 

Diaphragm Failure

Cavitation.

Enlarge pipe diameter on suction side of pump.

Excessive flooded suction 

pressure.

Move pump closer to product. Raise pump/place pump on top of tank to 

reduce inlet pressure. Install Back pressure device (Tech bulletin 41r). 

Add accumulation tank or pulsation dampener.

Misapplication (chemical/physical 

incompatibility).

Consult Chemical Resistance Chart for compatibility with products, 

cleaners, temperature limitations and lubrication.

Incorrect diaphragm plates or 

plates on backwards, installed 

incorrectly or worn.

Check Operating Manual to check for correct part and installation. 

Ensure outer plates have not been worn to a sharp edge.

Unbalanced 

Cycling

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime 

the pump in most cases.

Undersized suction line.

Meet or exceed pump connections.

Pumped fluid in air exhaust 

muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose 

diaphragm plate assembly.

Suction side air leakage or air in 

product.

Visually inspect all suction-side gaskets and pipe connections.

Check valve obstructed.

Disassemble the wet end of the pump and manually dislodge 

obstruction in the check valve pocket.

Check valve and/or seat is worn 

or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if 

necessary.

Entrained air or vapor lock in 

chamber(s).

Purge chambers through tapped chamber vent plugs.

TROUBLESHOOTING GUIDE 

(CONT.)

Summary of Contents for MAX-FLO MY1-25 METAL Series

Page 1: ...AIR OPERATED DOUBLE DIAPHRAGM PUMP Assembly Installation Operation Manual V1 0 2021 MY1 METAL NON METAL SERIES 25 MAX FLO...

Page 2: ...Pump Specifications 4 Explanation of Pump Nomenclature Technical Specifications Performance Curve Material Profiles 3 Recommended Installation Guide 6 4 Troubleshooting Guide 7 5 Dimension Drawing 9...

Page 3: ...t of a diaphragm rupture material can be forced out of the air exhaust muffler If product is hazardous or toxic pipe exhaust to appropriate safe area WARNING Chemical Hazard This pump is used for tran...

Page 4: ...g PERFORMANCE CURVE 0 2 4 6 8 Pressure bar 0 28 56 84 112 10 140 Pressure psi 0 20 40 60 80 100 120 140 0 5 2 10 4 15 6 20 8 26 0 31 2 36 4 160 41 6 Q l min Q usgpm Measured with 20 C Water Air Consum...

Page 5: ...and alkali not suitable solvent Can replace the EPDM EPR material 104 C 29 C Hytrel Good abrasion resistance used in most of the neutral fluid Can replace Bune N materials 104 C 29 C EPDM Abrasion re...

Page 6: ...R SUPPLY Connect the pump air inlet to an air supply with sufficient capacity and pressure to achieve desired performance A pressure regulating valve should be installed to insure air supply pressure...

Page 7: ...d Valve ball s not seating properly or sticking Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket Clean out around valve ball cage and valve seat area Rep...

Page 8: ...xcessive inlet pressure or air pressure Consult Chemical Resistance Chart for compatibility with products cleaners temperature limitations and lubrication Premature Diaphragm Failure Cavitation Enlarg...

Page 9: ...DRAWING NON METAL Discharge 1 ANSI 150 Flange Air inlet 1 2 BSPT NPT Suction 1 ANSI 150 Flange Air outlet 3 4 BSPT NPT STAINLESS STEEL Discharge 1 BSPT NPT Air inlet 1 2 BSPT NPT Suction 1 BSPT NPT Ai...

Page 10: ...NTER BLOCK NON METAL M02 M03 M04 M05 M06 M07 M08 M09 M10 M11 M12 M15 M14 M13 254 M16 M17 M19 M18 M01 2507 251 1 251 2 251 3A 2509 2506 2505 2504 2501 253 1 2502 2503 252 ALUMINUM M02 M03 M04 M05 M06 M...

Page 11: ...Reversing pin O ring 2 M06 PM Piston 2 M07 VT Piston V ring 2 M08 AL Upper pilot valve 1 M09 VT Pilot valve O ring 1 M10 PM Bottom Pilot valve 1 M10 CM Air End Parts Part Number Description Quantity M...

Page 12: ...Bottom Elbow 2 253 1 AL 253 1 KV 252 KV Fluid Chamber 2 252 PP 252 AL 252 SS 252 LL 254 AL Air chamber 2 2501 TF Valve Ball 4 2501 ST 2501 HY 2501 BN 2501 EP 2501 SS 2501 LL 2501 CM Wet End Parts Part...

Page 13: ...ENTER BLOCK MA2 MA3 MA4 MA5 MA6 MA7 MA8 MA9 MA11 MA12 MA13 MA14 MA15 MA16 MA17 MA10 25 MA1 2507 251 1 251 2 251 3P 2509 2506 2505 2504 2501 253 1 2502 2503 252 NON METAL MA2 MA3 MA4 MA5 MA6 MA7 MA8 MA...

Page 14: ...AINLESS STEEL Air End Parts Part Number Description Quantity MA1 KV Air valve housing 1 MA2 SS Plug locking plate 2 MA3 PM Piston 1 MA4 VT Piston V Ring 2 MA5 VT Plug O Ring 2 MA6 KV Plug 2 MA7 PM Pil...

Page 15: ...2 253 1 AL 253 1 KV 252 KV Fluid Chamber 2 252 PP 252 AL 252 SS 252 LL 2501 TF Valve Ball 4 2501 ST 2501 HY 2501 BN 2501 EP 2501 GE 2501 VT 2501 PC 2501 SS 2501 LL 2501 CM Wet End Parts Part Number De...

Reviews: