background image

 
 

 

■  POLE Mounting 

 

ST45L/ST56L-Series 

ST80L-Series 

Standard 

SCREW & NUT 18mm 

SCREW & NUT 24mm 

L-type bracket 

LB18 

LB24 

Wall Mounting-

type bracket 

LW18 

LW24 

round type bracket  SZ18 

SZ24 

bendable round 

type bracket 

SL18 

SL24 

* Please refer to below 6 Wiring Instruction-2 for the detail of bracket. 

 

 

There are 4 main methods of Tower Lamp installation in 

accordance with the locational condition or purpose of the 

installation. By referring to the followings, select the method of 

installation corresponding to the product. 

 

Style 

Size 

18mm 

SCREW & NUT 

(standard) 

Standard types 

 

24mm 

SCREW & NUT 

(standard) 

Standard types 

 

LB18 

 

LB24 

 

LW18 

 

LW24 

 

SZ18 

 

SZ24 

 

SL18 

 

SL24 

 

 

 

 
▪  Please  do  not  connect  power  line  to  the  signal  line  of 

steady/flashing type. Do use a point of contact without power 
line. 

▪  When changing lens kit, please do not pull with a strong power. 

It can cause a break of lens kit.   

▪ When wiring is complete, make sure end of any unused wires 

are insulated by tape. A short circuit of signal line can cause a 
trouble. 

▪ If using voltage is seriously higher or lower than rated voltage, 

it  can  reduce  the  self-life  of  the  product  or  can  cause  a 
problem  on  product  operating.  Make  sure  the  using  voltage 
does not /-5% of the rated voltage. 

▪  If  lens  or  body  of  the  product  is  contaminated  by  chemicals 

such  as  thinner,  benzene,  the  product  can  be  damaged, 
discolored or deformed. Please be careful. 

▪  Do  not  strongly  pull  the  wire  out  from  the  product.  It  can 

cause a disorder. 

 

 

 

 

Wiring Instruction -2 

  Caution 

 

Summary of Contents for ST45ML Series

Page 1: ...Buzzer type is IP23 1 ST45 M L ST45 M LF ST45 M L BZ ST45 M LF BZ Model Layer Voltage Current Weight Pole Color ST45 M L LED Steady ST45 M LF LED Steady Flashing ST45 M L BZ LED Steady build in buzzer ST45 M LF BZ LED Steady Flashing Build in Buzzer 1 AC DC12V 0 040A 0 29Kg RED R AC DC24V 0 040A 0 29Kg AC110V 0 024A 0 31Kg AC220V 0 012A 0 31Kg 2 AC DC12V 0 080A 0 33Kg RED R GREEN G AC DC24V 0 080A...

Page 2: ...AC220V 0 028A 0 62Kg 3 AC DC12V 0 360A 0 53Kg RED R AMBER A GREEN G AC DC24V 0 240A 0 53Kg AC110V 0 066A 0 77Kg AC220V 0 033A 0 77Kg 4 AC DC12V 0 480A 0 62Kg RED R AMBER A GREEN G BLUE B AC DC24V 0 320A 0 62Kg AC110V 0 075A 0 86Kg AC220V 0 037A 0 86Kg 5 AC DC12V 0 600A 0 70Kg RED R AMBER A GREEN G BLUE B WHITE W AC DC24V 0 400A 0 70Kg AC110V 0 082A 0 95Kg AC220V 0 041A 0 95Kg Signal line and Buzze...

Page 3: ...urrent 0 015A 0 028A 0 021A 0 038A ST56EL ST56ELF ST56EL BZ ST56ELF BZ Upper diagram is POLE Mounting ST56MEL ST56MELF ST56MEL BZ ST56MELF BZ Upper diagram is Direct Mounting 4 ST80 M L ST80 M LF ST80 M L BZ ST80 M LF BZ Model Laye r Voltage Current Weight Pol e Color ST80 M L LED Steady ST80 M LF LED Steady Flashing ST80 M L BZ LED Steady build in buzzer ST80 M LF BZ LED Steady Flashing Build in ...

Page 4: ...046A 0 69Kg AC220V 0 023A 0 69Kg 2 AC DC12V 0 160A 0 61Kg RED R GREEN G AC DC24V 0 080A 0 61Kg AC110V 0 051A 0 78Kg AC220V 0 025A 0 78Kg 3 AC DC12V 0 240A 0 69Kg RED R AMBER A GREEN G AC DC24V 0 120A 0 69Kg AC110V 0 057A 0 86Kg AC220V 0 028A 0 86Kg 4 AC DC12V 0 320A 0 78Kg RED R AMBER A GREEN G BLUE B AC DC24V 0 160A 0 78Kg AC110V 0 064A 0 95Kg AC220V 0 032A 0 95Kg 5 AC DC12V 0 400A 0 86Kg RED R A...

Page 5: ...2 0 3sq 400mm DC Steady Flashing AC Steady AC Steady Flashing Built in buzzer Power line UL1015 NO 18 0 75sq Ⅹ2C 400mm Signal line UL1007 NO 22 0 3sq 400mm In case of product using AC voltage connect the line without Polarity wire color In case of product using DC voltage black line is negative Steady DC ST45 M L DC ST56 M EL DC ST56 M L DC ST80 M EL DC ST80 M L DC Steady AC ST45 M L AC ST56 M EL ...

Page 6: ...r packing on top of lower lens kit is put inside upper lens 5 Assemble the product in reverse order of separating This product was manufactured with the structure for indoor use Outdoor use is prohibited Mount at the place where exists low vibration low impact low moisture and low dust as long as possible with vertical standing shape Refer to below information and drill necessary mounting holes on...

Page 7: ...18 SL24 Please do not connect power line to the signal line of steady flashing type Do use a point of contact without power line When changing lens kit please do not pull with a strong power It can cause a break of lens kit When wiring is complete make sure end of any unused wires are insulated by tape A short circuit of signal line can cause a trouble If using voltage is seriously higher or lower...

Page 8: ...age Making Sure Using Voltage Lighting but Non Flashing Wrong Wiring Making Sure Wiring No Sound Problem with speaker Contact Q Light or Their Agent Neither Lighting nor Flashing No sound Wrong Wiring Making Sure Wiring No Power Supply Making Sure Power Supply Trouble shooting Q LIGHT CO LTD http www qlightkr com E mail qlightkr qlightkr com Overseas Marketing Team Plant Tel 055 328 4082Fax 055 32...