Rolera Bolt  USER MANUAL

CHAPTER 5

TROUBLESHOOTING 

Resolving Problems with the Camera

The Green LED is not lit. 

 

Check all the cable connections. 

 

If your camera is still not lit, then your camera may not be receiving the required power. If you have 
an external power supply that outputs the power requirements needed to operate the Rolera Bolt, 
connect the camera to that external power supply. 

Image occasionally goes bright on one side or stays dark on one side 

Turn off the overhead lights in the room. Fluorescent lights may interact with the camera to create fluctuating 
image brightness.  

Hazy image or poor contrast 

 

If you are using the camera on a microscope, check the magnification of the microscope coupler. 
Consult your microscope manufacturer to find the type of coupler that works optimally with the 
Rolera Bolt camera’s sensor. 

 

Point the camera at something in the far distance. Loosen the locking washer on the outside of the 
C-mount ring. Adjust the C-mount ring until the image is in focus. Then tighten the locking washer 
so that the C-mount ring does not move. 

 

This effect may also be caused by excessive infrared (IR) illumination. Verify that your camera or 
optical system is blocking the IR. Contact QImaging to order an IR filter. 

Images that do not appear “sharp” 

If the image does not seem “sharp,” check the format of the lens or the coupler being used on the 
microscope. An incorrect coupler on the microscope will not provide the correct field of view, and will reduce 
the light available to the sensor. If you experience an “unsharp” image, contact your microscope dealer to 
assist you in finding the most appropriate coupler. 

Summary of Contents for Rolera Bolt CMOS

Page 1: ......

Page 2: ...maging or other hardware software or service providers and are used herein for identification purposes only Microsoft and Windows are registered trademarks in the U S and other countries of Microsoft...

Page 3: ...tended Product Warranty Plan includes parts and labor and is available in one year increments up to five years If needed QImaging also offers a Camera Loan Program When you purchase an Extended Produc...

Page 4: ...the Rolera Bolt 3 Connecting the the camera to a PC MAC desktop computer 3 CAMERA BASICS 5 Turning the Camera On and Off 5 Connecting the Rolera Bolt to Your Optics 5 Understanding the LED Indicators...

Page 5: ...ral resolution The USB 2 0 digital interface allows easy installation with a single cable for both power and data communication and eliminates the need for a framegrabber or external power supply The...

Page 6: ...age data transfer from the camera to the computer Cables A USB 2 0 interface cable is included with the camera One end of this cable connects to the available USB port on the back of the camera the ot...

Page 7: ...nce you have identified the USB ports in your computer you are ready to install the camera drivers and imaging software See your Imaging Software User s Guide for complete installation instructions Ca...

Page 8: ...rights reserved QI_BOLT_UM_RevA1 4 Rolera Bolt USER MANUAL Figure 2 Camera USB B and Power Sockets Plug the USB A end of the cable into a USB A port on your computer Figure 3 USB B to A Port Connectio...

Page 9: ...EEN LED will turn on Connecting the Rolera Bolt to Your Optics The Rolera Bolt connects directly to widely available C mount optics which are standard on most microscopes and lenses To attach the came...

Page 10: ...rical gain controls allow the user to map an image s intensities of interest to the camera s digital range This mapping is performed in the analog domain and thus avoids the quantization errors incurr...

Page 11: ...camera s CMOS sensor and circuits are sensitive to static discharge Ensure you are using a static strap or are completely grounded at all times to release any static energy before you clean the CMOS...

Page 12: ...ion of the microscope coupler Consult your microscope manufacturer to find the type of coupler that works optimally with the Rolera Bolt camera s sensor Point the camera at something in the far distan...

Page 13: ...ng com support faq for a list of all frequently asked questions Your issue may be resolved in one of these faqs Visit http www qimaging com support contact and fill out a support form online with the...

Page 14: ...ically made up of many pixel elements whose intensities are interpreted by imaging software to display an image on the screen Dynamic Range The ratio of the saturation level of the CMOS to the readout...

Page 15: ...s nanosecond abbr unit of measure for exposure time ROI Region of Interest abbr Using software to actively select a specified region of the CMOS image to collect This results in a smaller image displa...

Page 16: ...www qimaging com 2013 QImaging All rights reserved QI_BOLT_UM_RevA1 12 Rolera Bolt USER MANUAL APPENDICES APPENDIX A Rolera Bolt Dimensions 3 360 3 741 2 426 2 800...

Page 17: ......

Reviews: