6
R
S
-
4
85
In the figure we find the preset point is No.1 with title
of “NO TITLE”. Move cursor by PAN LEFT/RIGHT
and modify data by TILT UP/DOWN. Press buttons for
one second to speed up operation. Press CLOSE button
to exit edit state and store modifications. The title of
preset point has 8 characters in maximum such as 0-9,
A-Z, +, - and space. Note: the first character should be
0-9 or A-Z, otherwise it means to delete the title of the
preset point, and when preset point is adjusted, only
“NO.XXX” spears without title to be displayed.
IV. Setup of the Dome Camera
1. Connection of the System
1) The Systematic Drawing of the Dome Camera
C
Monitor
AC90
AC260V Input
Power Adapter
AC24V OUT
Power IN
VIDEO OUT
V
Multiplexer
Speed Dome
Matrix
RS-485
RS-485
RS-485
RS-485
Protocol Adapter
Protocol Adapter
Code Converter
B S W
B S W
RS232
AD Matrix
Philips Matrix
Figure 1
2) Address / Protocol Coding Switch Drawing
3 2 1
JP
SW2
ON
1
2
3
4
5
6
SW1
ON
1
2
3
4
5
6 7
8
9 10
120
term inal resistor is
connected on R S485 B us
Protocol Select
Speed Dome Address Select
3 2 1
JP
3 2 1
SW2
SW1
120
term inal resistor is
JP
opened forR S485 bus
Vertical View
Connector Pin
Figure 2