background image

4

5

INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4.1) – HANWHA Q CELLS AUSTRALIA PTY LTD – EN

INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4.1) – HANWHA Q CELLS AUSTRALIA PTY LTD – EN

For additional information see the relevant datasheet of the module provided at www.q-cells.com.

PRODUCT LINE

Q.PRO-G4.1

Q.PLUS-G4.1

Type

Polycrystalline

Q.ANTUM / Dark

Area [m²]

1.67

1.67

Frame height [mm]

32

32

Weight [kg]

18.8

18.8

Max. system voltage V

SYS

 [V]

1000

1000

Max. reverse current [A]

20

20

Permissible temperature range

–40 °C to +85 °C (–40 °F bis +185 °F)

Junction box protection class

IP67 with bypass diode

Connector protection class

IP68

IP68

Fire protection class

C

C

Snow load [Pa]

1

5400

5400

Wind load [Pa]

1

4000

4000

Certificates

VDE Quality Tested; CE-compliant; IEC 61215 (Ed.2) see page 9 et sqq.; IEC 
61730 (Ed.1) Application Class A

1

   Test-load in accordance with IEC 61215

Validity

These instructions are only valid for crystalline solar 
modules from the company Q CELLS. Q CELLS assumes 
no liability for damage resulting from failure to observe 
these instructions. 

 

Ä

Please observe the wiring and dimensioning of the 
system.

 

Ä

The installer of the system is responsible for compliance 
with all necessary safety regulations during set-up and 
installation.

Q CELLS assumes no liability on the basis of these 
instructions. Q CELLS is only liable in the context of 
contractual agreements or in the context of accepted 
guarantees. Q CELLS accepts no other responsibility for 
the functionality and safety of the modules. 

 

Ä

Please observe the instructions for any other sys-
tem components that may be part of the complete  
solar power system. It may be necessary to carry out a 
structural analysis for the entire project. 

Additional information for the Operator

 

Ä

Please keep this manual for the entire life of the solar 
power system.

 

Ä

Please contact your system supplier for information 
concerning the formal requirements for solar power 
systems.

 

Ä

Please be sure to contact the relevant local authorities 
and energy providers regarding regulations and permit 
requirements prior to installation of the solar power 
system.

Other applicable documents

In addition to this Manual following technical information 
are relevant:

DOCUMENT TYPE

Product data sheet

Packaging and transport information

1 INTRODUCTION

2.1  Technical specifications

2 PLANNING

Fig. 1: 

 External dimensions (in mm) and components for Q.PRO-G4.1, Q.PLUS-G4.1

DETAIL A

16 mm

Junction bo×

Product label

1670 mm

4 × Fastening points (DETAIL A)

Cable with
connectors

Frame

1000 mm

32 mm

8 × Drainage holes

6 × Grounding points ø 4.5 mm

1000 mm

980 mm

150 mm

8.5 mm

24.5 mm

951 mm

Summary of Contents for Q.PRO-G4.1

Page 1: ...Valid for Australia and New Zealand Q PRO G4 1 Q PLUS G4 1 INSTALLATION AND OPERATION MANUAL...

Page 2: ...lar the installer as well as the operator of a module is responsible for compliance with all applicable statutory requirements and regulations Unless otherwise specified by any laws or regulations the...

Page 3: ...safety regulations during set up and installation Q CELLS assumes no liability on the basis of these instructions Q CELLS is only liable in the context of contractual agreements or in the context of...

Page 4: ...ion of the module Guarantees long term stability Avoid the usage of different metals to prevent contact corrosions Allows for stress free expansion and contraction due to temperature fluctuations Ensu...

Page 5: ...lection For detailed key electrical data please refer to the actual data sheet referring to the relevant Module available at www q cells com Only connect modules of the same type and power class Safet...

Page 6: ...he modules securely in cool and dry rooms The packaging is not weatherproof DANGER Risk of fatal injury due to electric shock Do not install damaged modules Inform your distributor of any damages imme...

Page 7: ...ules in windy or wet weather DANGER Risk of fatal injury due to electric shock Only use dry insulated tools Do not carry out the installation alone Only install undamaged modules and components Do not...

Page 8: ...modules are disconnected at the inverter prior to separation Be sure to observe the specified time intervals after switching off the inverter High voltage components need time to discharge DANGER Risk...

Page 9: ...tric shock Ensure that all electrical components are in a proper dry and safe condition Standard wiring with a return cable Inverter EN 4 3 Connection of modules 4 ELECTRICAL CONNECTION Ensure that al...

Page 10: ...t a loss of performance Maintenance The system should be inspected by an installer annually to check the following all system components sit securely and are corrosion free the connection is secure an...

Page 11: ...Level 14 20 Berry Street North Sydney NSW 2060 TEL 61 0 2 9016 3033 FAX 61 0 2 9016 3032 EMAIL service q cells com au WEB www q cells com au Subject to change without notice Hanwha Q CELLS Installati...

Reviews: