INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.POWER-G5 / L-G5 • Q.PRIME-G5 / L-G5 – EN
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.POWER-G5 / L-G5 • Q.PRIME-G5 / L-G5 – EN
Ä
Use solar cables for the connection at
the junction box outlet.
Ä
Use the same, inverter-compatible plugs.
SOLAR
NOTE
! Module damage may occur!
Ä
Ensure that the cabling is not under
stress.
Ä
Ensure that the cables do not run
between module and subconstruction
(danger of pinch).
Ä
Do not connect modules with different
orientations or angles of inclination in
the same string.
Ä
Ensure for a tight connection between
the plugs. Plugs click together
audibly.
Ä
To avoid contamination, male and female
connectors shall be connected within
one week after the modules are placed
on the racks of the plant
click
EN
DANGER
! Risk of fatal injury due to electric
shock!
Ä
Ensure that all electrical components are
in a proper, dry, and safe condition.
4.3 Connection of modules
4
ELECTRICAL CONNECTION
•
The 60-cell modules with min.
≥
1,000 mm and for the 72 cell modules
with min.
≥
1,200 mm long cable in
portrait orientation can be wired as a
“2nd next neighbor”
“2nd next neighbor” - Wiring without a
return cable.
Standard wiring with a return cable
Inverter
Inverter
1
2
Ä
Ensure that all necessary safety and
functional tests have been carried out
according to current industry standards.
NOTE
! Module damage may occur!
Ä
Ensure that the plug connections are
secured away from any water-channelling
surface.
Ä
Integrate the system into the existing
lightening protection system in
accordance with the applicable local
regulations.
WARNING
! Fire Risk!
Ä
Do not use light concentrators (e.g.
mirrors or lenses).
Ä
Ensure that the cabling is not exposed
and/or hanging and is protected from dirt
and moisture.
4.4 After installation
4
ELECTRICAL CONNECTION