0.39 in (10mm)

0.20 in 

(5 mm)

Option 1:

 

Ä

Fasten the module with 4 clamps  in the specified 
clamping range, see Fig. 2, p. 7.

 

Ä

Tighten clamps according to manufacturer’s 
instructions.

 

Ä

Maintain an interval of at least 0.39 in (10 mm) 
between two modules along the short side and 
0.20 in (5 mm) along the long side.

NOTE! Module damage may occur!

 

Ä

Do not subject modules to mechanical tension. 
Max. torsion 0.12 in/ft (10 mm/m).

Option 2:

 

Ä

Install the module at the 4 mounting points,  
see Fig. 2, p. 7.

 

Ä

Tighten screws according to manufacturer’s 
instructions.

Option 3:

 

Ä

Install the module using mounting profiles,  
see Fig. 2, p. 7.

3  INSTALLATION

3.3 MODULE INSTALLATION

DANGER! 
Risk of fatal injury due to electric shock!

When disconnecting an electric circuit carrying direct current, 
electric arcs can occur that may result in life-threatening injuries.

 

Ä

Do NOT unplug the cable when under load.

 

Ä

Do NOT connect any exposed cable ends.

 

Ä

Electrical work may only be performed by qualified and skilled 
personnel (see page 3).

A solar module generates electrical current and voltage even 
at a low intensity of illumination. Sparks and electric arcs may 
result from the separation of a closed circuit. These can result 
in life-threatening injuries. The danger increases when several 
modules are connected in series.

 

Ä

Please be aware of that the entire open circuit voltage is active 
even at low levels of solar irradiation. 

 

Ä

Please follow the valid national regulations and safety guidelines 
for the installation of electrical devices and systems.

 

Ä

Please make sure to take all necessary safety precautions. With 
module or phase voltages of more than 120 V, the safety extra-
low voltage range is exceeded.

 

Ä

Carry out work on the inverter and the wiring with extreme 
caution.

 

Ä

Ensure that the modules are disconnected at the inverter prior 
to separation.

 

Ä

Be sure to observe the time intervals specified by the inverter 
manufacturer after switching off the inverter.

 

Ä

Make sure that the plugs can not be connected unintentionally.

 

Ä

Before working on the contacts, check them for safety extra-
low voltage.

DANGER! Risk of fatal injury due to electric shock! 

 

Ä

Never open the junction box.

 

Ä

Do not remove bypass diodes.

DANGER! Risk of fatal injury due to electric shock! 

 

Ä

Never touch live contacts with bare hands.

 

Ä

Cover connectors by suitable protective caps until 
installation.

DANGER! Risk of fatal injury due to electric shock! 

 

Ä

Insulate any exposed cable ends.

 

Ä

Only connect cables with plugs.

DANGER! Risk of fatal injury due to electric shock! 

 

Ä

Only use dry, insulated tools for electrical work.

4  ELECTRICAL CONNECTION

4.1  SAFETY

Summary of Contents for Q.PEAK DUO ML-G9 Plus

Page 1: ...Valid for North America INSTALLATION AND OPERATION MANUAL Q PEAK DUO ML G9 X solar module series...

Page 2: ...pliance with all applicable statutory requirements and regulations The following regulations and standards must be upheld at all times during the installation operation and maintenance of the solar m...

Page 3: ...r applicable documents This installation manual is only valid in combination with the following technical information DOCUMENT TYPE Product data sheet Packaging and transport information MISUSE OR INC...

Page 4: ...hemounting system into the module except for the wind and snow loads Additional forces and moments of torque at the mounting positions caused by torsions displacements or vibrations in the mounting sy...

Page 5: ...ystem supplier The Q CELLS listed test load values were determined with the following clamp parameters clamp width 1 5in 38mm and clamp depth 0 39in 10mm The system installer is responsible for the de...

Page 6: ...g the maximum number of modules in the string Parallel Connection Modules may be damaged by the occurrence of reverse currents caused by module defects ground leaks or defective insulation Ensure that...

Page 7: ...NOTE Module damage may occur Never step on modules Do not subject modules to any mechanical stress Do not allow any objects to fall onto modules 3 INSTALLATION 3 1 SAFETY AND TRANSPORT DANGER Risk of...

Page 8: ...arcs may result from the separation of a closed circuit These can result in life threatening injuries The danger increases when several modules are connected in series Please be aware of that the ent...

Page 9: ...sonnel see page 3 Ensure correct polarity Use solar cables for the connection at the junction box outlet Only interconnect connectors of the same type and manufacturer Use minimum No 12 AWG copper wir...

Page 10: ...holes are marked with a ground symbol as shown below on the frame section drawing To install the grounding lug follow the specified instructions of the manufacturer The grounding lug should be made o...

Page 11: ...to be checked that the components are secure undamaged and clean Cleaning WARNING Risk of injury due to hot and live modules Only clean modules that have cooled down Do not carry or wear any electric...

Page 12: ...Spectrum Center Drive Suite 1400 Irvine CA 92618 USA TEL 1 949 748 59 69 EMAIL inquiry us q cells com WEB www q cells us Subject to change without notice Q CELLS Installation manual solar modules Q PE...

Reviews: