background image

4

5

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.MAXX-G3 – Q CELLS

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.MAXX-G3 – Q CELLS

Validity

These instructions are only valid for crystalline solar modules from 
the company Q CELLS as specified at chapter „2.1 Technical 
Specifications“. 
Q CELLS assumes no liability for damage resulting 
from failure to observe these instructions.

 

Ä

Please observe the wiring and dimensioning of the system.

 

Ä

The installer of the system is responsible for compliance with all 
necessary safety regulations during set-up and installation.

Q CELLS assumes no liability on the basis of these instructions. 
Q CELLS is only liable in the context of contractual agreements 
or in the context of accepted guarantees. Q CELLS accepts no 
other responsibility for the functionality and safety of the modules.

 

Ä

Please observe the instructions for any other system compo-
nents that may be part of the complete solar power system. 
It may be necessary to carry out a structural analysis for the 
entire project.

Additional information for the Operator

 

Ä

Please keep this manual for the entire life of the solar power 
system.

 

Ä

Please contact your system supplier for information concerning 
the formal requirements for solar power systems.

 

Ä

Please be sure to contact the relevant local authorities and 
energy providers regarding regulations and permit requirements 
prior to installation of the solar power system.

Other applicable documents

In addition to this Manual following technical information are 
relevant:

DOCUMENT TYPE

Product data sheet

Packaging and transport information

Fig. 1: 

External dimensions and components for 
Q.MAXX-G3

DETAIL A

16 mm

8.5 mm

24.5 mm

1088 mm

1840 mm

4 × Mounting slots (DETAIL A)

Frame

1030 mm

981 mm

32 mm

8 × Drainage holes

376 mm

EN

4 × Grounding points ø 4.5 mm

Label

1200 mm

1200 mm

For additional information see the relevant datasheet of the module provided at www.q-cells.com/au.

PRODUCT LINE

Q.MAXX-G3

Type

Q.ANTUM DUO Z

Length

1840 mm

Width

1030 mm

Frame height

32 mm

Area

1.90 m²

Weight

19.5 kg

Max. system voltage V

SYS

1000 V

Max. reverse current

20 A

Permissible 

temperature range

–40 °C to +85 °C (–40 °F to +185 °F)

Junction box 

protection class

IP67 with bypass diode

Connector protection class

IP68

Fire rating based on 

ANSI / UL 61730

C / Type  2

Max. test load Push / Pull

1

6,000 Pa / 4,000 Pa

Max. design load Push / Pull

1

4,000 Pa / 2,660 Pa

Certificates

CE-compliant; IEC 61215:2016; IEC 61730:2016; PV module classification: Class II; 
UL 61730

1

 Test and design load in accordance with IEC 61215:2016, depending on mounting options (see section „2.3 Mounting Options“)

1  INTRODUCTION

2  PLANNING

2.1  TECHNICAL SPECIFICATIONS

Summary of Contents for Q.MAXX-G3 Series

Page 1: ...INSTALLATION AND OPERATION MANUAL Q MAXX G3 solar module series Valid for Africa Europe LatinAmerica South America DRAFT...

Page 2: ...such as country specific regulations for pressure equipment operational safety hazardous goods and environmental protection Regulations and requirements specific to the system Any applicable laws and...

Page 3: ...or solar power systems Please be sure to contact the relevant local authorities and energyprovidersregardingregulationsandpermitrequirements prior to installation of the solar power system Other appli...

Page 4: ...g substructure Ensures sufficient rear ventilation of the module Avoid the usage of different metals to prevent contact corrosion Allows for stress free expansion and contraction due to temperature fl...

Page 5: ...The system installer is responsible for the determination of location specific load requirements CL1a at high loads 5400 4000Pa The clamp position is variable in the given range but the distance betwe...

Page 6: ...maged by the occurrence of reverse currents caused by module defects ground leaks or defective insulation Ensure that the maximum reverse current load capacity indicated in the data sheet is met In or...

Page 7: ...le damage may occur Never step on modules Do not subject modules to any mechanical stress Do not allow any objects to fall onto modules 3 INSTALLATION 3 1 SAFETY AND TRANSPORT Danger Risk of fatal inj...

Page 8: ...m the separation of a closed circuit These can result in life threatening injuries The danger increases when several modules are connected in series Please be aware of that the entire open circuit vol...

Page 9: ...nel see page 3 Ensure correct polarity Use solar cables for the connection at the junction box outlet Only interconnect connectors of the same type and manufacturer Use minimum 4mm2 copper wires insul...

Page 10: ...nical friction Ensure that cables are protected from abrasion tension compression and cutting forces in full accordance with AS NZS 3000 and all other relevant standards 4 ELECTRICAL CONNECTION 4 4 AF...

Page 11: ...y conductive parts WARNING Risk of falling due to unsecured access Never access the installation area alone or without taking adequate security precautions Please commission a trade specialist NOTE Mo...

Page 12: ...n manual solar modules Q MAXX G3_2020 11_Rev01_AU HANWHA Q CELLS AUSTRALIA PTY LTD Suite 1 Level 1 15 Blue Street North Sydney NSW 2060 Australia TEL 61 0 2 9016 3033 FAX 61 0 2 9016 3032 EMAIL q cell...

Reviews: