P01P
Unknown
Unregistered Failure
It is an unregistered fault. Turn off and restart
the system. Please contact the Q CELLS
Service –Hotline, if an error occurs
continuously.
P03P
DSP-EMG
TRIP P
DSP-Emergency
Trip Protection
Please check emergency switch.
Type : PROTECTION
WEB Display
HMI Display
Description
Measures
6.7.3 System General Events (Protection)
P11P
ADC P
ADC Measure Error
Protection
Please turn off and restart the system.
If an error occurs repeatedly, it is necessary
to replace the Control Board.
P12P
DSPM
UPDATE P
DSP Master Remote
Update Fail Protection
Please update DSP Master software again.
P13P
DSPS
UPDATE P
DSP Slave Remote
Update Fail Protection
Please update DSP Slave software again.
P14P
PMS
UPDATE P
PMS Remote Update
Fail Protection
Please update PMS software again.
[ Table 6-13 : System General Events Protection List ]
P15P
DSP VER P
DSP Firmware Version
Error Protection
DSP and PMS versions are different.
Please re-install the DSP software.
P16P
PMS VER P
PMS Firmware Version
Error Protection
Please update DSP Slave software again.
P21P
DSPM
FRAM P
DSP Master FRAM
Communication Error
Protection
Please turn off and restart the system.
If an error occurs repeatedly, it is necessary
to replace the Control Board.
P22P
DSPS
FRAM P
DSP Slave FRAM
Communication Error
Protection
Please turn off and restart the system.
If an error occurs repeatedly, it is necessary
to replace the Control Board.
P23P
DSP COM P
DSPM-DSPS
Communication Error
Protection
It is an unregistered fault. Turn off and restart
the system. Please contact the Q CELLS
Service–Hotline, if an error occurs
continuously.