Page 1: ...1 SP 395T TTA Fluorometer Operation Manual Version 1 2 November 2018 ...

Page 2: ...s 5 1 5 Optional Accessories 5 1 6 Light Shield Cover 6 2 Start SP 395T 6 2 1 Battery Installation 6 2 2 Description of the Control Keys 7 2 3 Turning On Off SP 395T 8 3 Wireless Connection 8 4 Device Information and Diagnosis 9 5 TTA Measurement 10 5 1 High Color and Turbidity Warning 10 6 Calibration 11 7 Cleaning Procedure for SP 395T Sample Wall 12 ...

Page 3: ...e Pyxis warrants that any labor services provided shall conform to the reasonable standards of technical competency and performance effective at the time of delivery All service interventions are to be reviewed and authorized as correct and complete at the completion of the service by a customer representative or designate Pyxis warrants these services for 30 days after the authorization and will ...

Page 4: ...of and waterproof 1 2 Pyxis SP 395T Major Features The Pyxis SP 395T analyzer is an ultraviolet fluorometer It measures non halogenated Tolytriazole TTA directly without reagent Main features include Sample acidification is not required TTA measurement is independent of sample pH in the range of 6 to 10 Extra color and turbidity parameters measured are used for automatic compensation to eliminate ...

Page 5: ...issing or damaged please contact Pyxis Customer Service at service pyxis lab com 1 4 Standard Accessories Quick instruction guide 9V alkaline battery Full instrument manual is available by emailing your request to service pyxis lab com or visiting www pyxis lab com 1 3mL Transfer Pipet 1 5 Optional Accessories MA 700 Carry Case for SP395T Part 50725 Pyxis Handheld Cleaning Kit Solution Part SER 02...

Page 6: ...conds and then automatically turn off Replace the battery to resume operation of the SP 395T after the battery warning The SP 395T will automatically turn on in the measurement mode after new battery installation The SP 395T battery compartment shown in Figure 2 is on the back side of the instrument Install battery as follows 1 Remove the battery compartment cover by loosening two screws Make sure...

Page 7: ...ease firmly tighten the two screws 2 2 Description of the Control Keys The SP 395T has three keys as shown in Figure 1 The left right and OK keys are used to launch an action indicated on the screen directly above the keys Please note that the screen is not a touch screen The labels above the keys indicate the function associated with the keys and can change according to the screen modes ...

Page 8: ... 60 seconds without user interaction through the keys 3 Wireless Connection The Pyxis SP 395T can be connected to a smart phone or a computer via Bluetooth WiFi for upgrading the device software The SP 395 can be wirelessly paired with other Pyxis devices for exchanging data In the normal operation modes the wireless function is turned off If you want to explore the SP 395T wireless functions plea...

Page 9: ...e 4 The battery life as a percentage and the standard that were used in the last calibration are also shown Press the Diagnosis labeled key to switch to the diagnosis screen where raw measurement data are displayed Figure 5 The information has no use for normal operation Please provide an image of both the device information screen and the diagnosis screen when you contact Pyxis service pyxis lab ...

Page 10: ... ppm The SP 395T does not need to be turned off between measurements of two samples Rinsing the measurement cell several times is recommended 5 1 High Color and Turbidity Warning Background Fluorescence The SP 395T has extra channels to measure sample turbidity and color These measured parameters are used in internal algorithms to automatically compensate sample color and turbidity interference fr...

Page 11: ...d press ZERO to finish the zero calibration step If the zero calibration is successful a check mark will be displayed next to Press Zero Button If any abnormal signal is detected an error message will be shown Rinse the sample cell using the 3mL Transfer Pipet with the 1 ppm TTA standard Fill the sample cell using 3mL Transfer Pipet with the 1 ppm standard close the light shield and press Slope to...

Page 12: ...12 ...

Page 13: ...l of this film contamination Pyxis recommends a minimum cleaning frequency of once per month be maintained dependent on application needs and foulant level High stress applications with excessive suspended solids and corrosion scale by product can result in the need to increase the frequency of cleaning your handheld device For field use Pyxis has developed a custom field cleaning kit for all your...

Page 14: ... soak for 30 minutes Then use cotton swab or soft cloth to gently remove excessive deposit after soaking Rinse with DI water then check for flashing blue light inside your handheld device If surface is not entirely clean soak the device for an additional 30 minutes then repeat check ...