Figure 5. Display/Processor Module Dimension, inch (mm)
The display/processor module of the LSP Series sensor can be installed to a 1-inch bulkhead fitting on the top
of the tank. Alternatively, you may also use the LSP Series Mounting Bracket (P/N: 50770) for installations
where top tank mount may be to too high for visual display verification. In this format, the display/processor
module is installed in a location away from the tank top to take the advantage of the 32.8-foot cable and have
visibility to the display. Each LSP Series sensor is also shipped with a 2” male NPT bulkhead adapter with
internal cable gland (pre-installed on transducer cable) for installations requiring a sealed bulkhead/cable
fitting as shown in Figure 6.
Figure 6. LSP Series Mounting Bracket (P/N: 50770) w/ 2” male NPT bulkhead adapter
The following is a list of installation guidelines and precautions:
1. Leave a 1-inch space between the transducer module and the tank bottom surface.
2. Do not remove the protective cap and expose the diaphragm directly to the liquid. This may cause
permanent sensor damage.
3. Ensure that installation is not near large vibration locations.