background image

Warranty Information

Confidentiality

The information contained in this manual may be confidential and proprietary and is the property of Pyxis
Lab, Inc. Information disclosed herein shall not be used to manufacture, construct, or otherwise reproduce
the goods described. Information disclosed herein shall not be disclosed to others or made public in any
manner without the express written consent of Pyxis Lab, Inc.

Standard Limited Warranty

Pyxis Lab warrants its products for defects in materials and workmanship. Pyxis Lab will, at its option, repair
or replace instrument components that prove to be defective with new or remanufactured components
(i.e., equivalent to new). The warranty set forth is exclusive and no other warranty, whether written or oral,
is expressed or implied.

Warranty Term

The Pyxis warranty term is thirteen (13) months ex-works. In no event shall the standard limited warranty
coverage extend beyond thirteen (13) months from original shipment date.

Warranty Service

Damaged or dysfunctional instruments may be returned to Pyxis for repair or replacement. In some in-
stances, replacement instruments may be available for short duration loan or lease.

Pyxis warrants that any labor services provided shall conform to the reasonable standards of technical com-
petency and performance effective at the time of delivery. All service interventions are to be reviewed and
authorized as correct and complete at the completion of the service by a customer representative, or des-
ignate. Pyxis warrants these services for 30 days after the authorization and will correct any qualifying
deficiency in labor provided that the labor service deficiency is exactly related to the originating event. No
other remedy, other than the provision of labor services, may be applicable.

Repair components (parts and materials), but not consumables, provided during a repair, or purchased
individually, are warranted for 90 days ex-works for materials and workmanship. In no event will the in-
corporation of a warranted repair component into an instrument extend the whole instrument’s warranty
beyond its original term.

Warranty Shipping

A Repair Authorization (RA) Number must be obtained from Pyxis Technical Support before any product can
be returned to the factory. Pyxis will pay freight charges to ship replacement or repaired products to the
customer. The customer shall pay freight charges for returning products to Pyxis. Any product returned to
the factory without an RA number will be returned to the customer. To receive an RMA you can generate a
request on our website at

https://pyxis-lab.com/request-tech-support/

.

Pyxis Technical Support

Contact Pyxis Technical Support at +1 (866) 203-8397,

[email protected]

or by filling out a request for

support at

https://pyxis-lab.com/request-tech-support/

.

ST-600 Series User Manual

[email protected]

| +1 (866) 203-8397

1

Summary of Contents for 50219

Page 1: ......

Page 2: ...Series Bleach Concentration Sensor User Manual April 28 2021 Rev 3 01 Pyxis Lab Inc 1729 Majestic Dr Suite 5 Lafayette CO 80026 USA www pyxis lab com 2017 Pyxis Lab Inc Pyxis Lab Proprietary and Confi...

Page 3: ...Connecting to uPyxis Mobile App 9 5 3 Calibration Screen and Reading 10 5 4 Diagnosis Screen 11 5 5 Device Info Screen 12 6 Setup and Calibration with uPyxis Desktop App 12 6 1 Install uPyxis Desktop...

Page 4: ...very All service interventions are to be reviewed and authorized as correct and complete at the completion of the service by a customer representative or des ignate Pyxis warrants these services for 3...

Page 5: ...3 inline tee assemblies as an accessory option if required Teflon Tube Installation Format The second method is to install the sensor in line using the unique 1 4 OD 7 mm OD clear Teflon tubing adapte...

Page 6: ...readed ports Cable Length 5 ft with IP67 connectors 2 ft flying lead with IP67 adapter Power Supply 22 26 VDC 2W Dimension L Dia 6 8 1 44 inch 172 7 36 6 mm Weight 0 37 lbs 170 g Material CPVC Operati...

Page 7: ...t P N ST 001 7 Pin Female Adapter Flying Leads Cable 2 ft P N MA 1100 Clear Teflon Tubing 1 4 OD 6 Adapter User Manual available online at https pyxis lab com support 3 2 Optional Accessories Figure 1...

Page 8: ...bubble interfer ence Pyxis also offers 2 and 3 inline tee assemblies as an accessory option if required To properly install the ST 600 Series sensor into the ST 001 Tee Assembly follow the steps belo...

Page 9: ...e darkening prior to and after the optical channel as seen in Figure 3 Figure 3 ST 600 Series sensor with clear Teflon tube adapter 4 3 Wiring If insufficient wattage is available from the connected c...

Page 10: ...onnection to ST 600 Series sensor 4 5 Connecting via USB A USB RS485 adapter P N MA 485 can be used to connect a ST 600 Series sensor to a computer with the uPyxis Desktop App NOTE Using non Pyxis USB...

Page 11: ...with uPyxis Mobile App 5 1 Download uPyxis Mobile App Download uPyxis Mobile App from Apple App Store or Google Play Figure 6 uPyxis Mobile App installation ST 600 Series User Manual service pyxis la...

Page 12: ...1 Open uPyxis Mobile App 2 On uPyxis Mobile App pull down to refresh the list of available Pyxis devices 3 If the connection is successful the ST 600 Series and its Serial Number SN will be displayed...

Page 13: ...t to the Calibration screen From the Calibration screen you can perform calibrations by pressing on Zero Calibration Slope Calibration and 4 20mA Span Follow the screen instructions for each calibrati...

Page 14: ...screen you can check the diagnosis condition as well as Export Upload This feature may be used for technical support when communicating with service pyxis lab com Figure 9 ST 600 Series User Manual s...

Page 15: ...package will download and install the Microsoft Net Framework 4 5 if not previously installed on the PC the USB driver for the USB Bluetooth adapter MA NEB the USB RS485 adapter MA 485 and the main u...

Page 16: ...r 2 Launch uPyxis Desktop App 3 On uPyxis Desktop App click Device Connect via USB Bluetooth or Connect via USB RS485 Fig ure 12 4 If the connection is successful the ST 600 Series sensor and its Seri...

Page 17: ...n description for Device Name Product Name and Modbus Address then click Set to save Figure 13 6 4 Calibration Screen To calibrate the device click on Calibration On the Calibration screen there are t...

Page 18: ...or technical support when communicating with service pyxis lab com Figure 15 7 Outputs 7 1 4 20mA Output Setup The 4 20mA output of the ST 600 sensor is scaled as Sodium Hypochlorite 4 mA 0 20 mA 16 T...

Page 19: ...op App click 4 20mA Span found on the Calibration Screen shown in Figure 17 Figure 16 Figure 17 7 3 Communication using Modbus RTU The ST 600 Series sensor is configured as a Modbus slave device In ad...

Page 20: ...nd cleaned if required It is sug gested that the ST 600 Series sensor be checked for fouling and cleaned calibrated on a monthly basis Heavily contaminated waters may require more frequent cleanings C...

Page 21: ...ield the ST 600 Series sensor from direct sunlight and precipitation 9 Troubleshooting If the ST 600 Series sensor output signal is not stable and fluctuates significantly make an additional ground co...

Reviews: