Unsetting The Panel 

The panel may be unset by entering the building via the entry/exit route and then entering 
either the Master Code or any of the Limited User Codes. 

Enter 

 

(User Code) 

Reset After Alarm Condition 

Enter 

 

User code to stop alarm 

Enter 

 

User code to reset the system 

If the panel will not reset then your installer has enabled engineer or anti code reset, please 
contact your installation company.  

Duress Set/Unset 

Enter 

 (User Code)  Reverse the last two digits of the code. 

The panel will then appear normal but a Duress Code will be sent to the Central Receiving 
Station. 

Personal Attack Alarm (PA) 

To Activate the Personal Attack Alarm enter 

. Enter a user code to cancel. 

Fire Alarm  

To Activate the Fire Alarm enter 

. Enter a user code to cancel. 

Turning Chime On and Off

 (Panel must be in ‘day’ mode 

Enter 

. The status of the chime facility is indicated by the ‘chime’ LED on the front 

of the control panel.  When the chime mode is selected a two tone chime will be produced by 
the internal sounder and any extension speakers when an Entry / Exit zone is activated. The 
same key sequence may be used to turn off the chime facility. 

Reading The Event Log 

Panel must be in ‘day’ mode  

Enter 

. The ‘day’ led will flash and the most recent event stored in the log will be 

displayed.  

If the up arrow key 

 is pressed the previous log entry will be displayed. Similarly if the 

down arrow key 

 is pressed the next most recent entry will be displayed. The event log 

may be scrolled backwards and forwards using the up and down arrow keys to allow the last 
100 events to be viewed. 

To leave this function press the 

 key.  

An error tone will be produced if an attempt is made to scroll outside either end of the event 
memory log.  

Refer to the table below for the symbols stored in the event log and their meanings. 

Symbol 

 

Meaning

 o   

Activation of a programmable zone. 

 

Keyswitch Activation 

 

This shows that a zone was omitted and refers to the number which precedes it in 
the log 

 

Keypress tamper - Four attempts cause a tamper fault. 

 

Keypad Personal attack activation. 

 

Engineer Code Entered. 

 

Keypad Fire alarm activation. 

 

Set A 

 

Set B 

 

Set C 

 

Set D 

 

Unset 

 

System Fault 

MASTER ONLY FUNCTIONS 

Event Log Reset 

Enter: 

  

This feature will only operate if, whilst programming, the engineer selected the feature 
allowing the Master User to clear the event log. 

4

 RINS137-7 RINS137-7 

5

 

Intelligent Security & Fire Ltd

Summary of Contents for STERLING 10

Page 1: ...MJOH 10 USER GUIDE ARM MODE A ARM MODE B ARM MODE C ARM MODE D TM 8 A B C D 2 1 3 4 SET 5 6 7 8 9 0 INSTALLER DETAILS TELEPHONE X X X X X X X X A B C D OR I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 2: ... the event log by entering A O symbol followed by 1 4 will be displayed There are two levels of user access to the system The Master Code Code 1 allows access to all user functions and programming features 1 Bell Fuse Fail 2 Auxiliary Fuse Fail 3 Telephone Line Fail 4 Mains AC Fail The User Codes Codes 2 to 6 allow arming disarming of the panel enabling and disabling of the door chime and viewing ...

Page 3: ... PTS button is pressed The numbers of any activated zones will be entered into the event log Zones programmed as Keyswitch zones when activated in walk test will not be entered in the event log Final Door Set Changing Master and Limited User Codes Set the panel in any of the above methods the panel will count down but will not set until the final exit door is opened then closed Master Code Enter f...

Page 4: ...used to turn off the chime facility Reading The Event Log Panel must be in day mode Enter The day led will flash and the most recent event stored in the log will be displayed If the up arrow key is pressed the previous log entry will be displayed Similarly if the down arrow key is pressed the next most recent entry will be displayed The event log may be scrolled backwards and forwards using the up...

Reviews: