MASTER AND LIMITED USER FUNCTIONS 

Test Mode 

Enter 

 

Setting the Panel 

Enter 

 (User Code) 

 and then 

or

 for set required. 

Refer to the Zone Programming Status Label to see how each set was configured by the 
installation engineer. 

This function performs a number of tests which are listed below.  The next test is selected by 
pressing any numeric key. 

Test 

1) 

All LEDs are switched on except the fault LED. 

 

2) 

The strobe is switched on. 

Setting the Panel when the Mains Fails 

 

3) 

The bell is switched on. 

 

4) 

The internal sounder is switched on. 

Under normal operation the panel will indicate a fault condition if the AC supply is 
disconnected. It will still be possible to Set and Unset the panel during a mains fail only if 
allowed by the engineer, and no further action is required. Full functionality of the panel is 
available during a mains failure. 

To exit test mode press the 

 key again. 

Walk Test Mode 

Silent Setting of the Panel 

Enter 

 followed by 

 the master code and the set option, either 

 

 - 

 - 

 or 

Enter 

 and then 

or

 for set required. 

A dual tone will be heard on acceptance of the command, and another dual tone will be heard 
when the panel is set. 

When the walk test mode is enabled the ‘chime’ LED will flash. If the panel is then set each 
active zone will cause a chime when triggered. This enables all the zone configurations to be 
walk tested individually. The walk test mode is cleared when the panel is unset.  

Push to Set 

Set the panel in any of the above methods. The panel will count down, but will not set until the 
PTS button is pressed. 

The numbers of any activated zones will be entered into the event log.  Zones programmed 
as Keyswitch zones when activated in walk test will not be entered in the event log. 

Final Door Set 

Changing Master and Limited User Codes 

Set the panel in any of the above methods, the panel will count down but will not set until the 
final exit door is opened then closed. 

Master Code 

Enter 

 

 followed by 

 Master User Code (factory set at 1 2 3 4) 

Arm with Omits 

If any zones are triggered whilst in ext mode a low pitched error tone will be heard, any faulty 
zones will be displayed in the seven segment display. First check for any obvious reason for 
these zones to have been activated.  

Enter    

 Enter the new code twice, three tones will be heard on acceptance of each command, a 
single low tone indicates programming not accepted. 

This may simply be due to a monitored door or window being left open or a pet being left in a 
protected area. If the fault cannot be rectified it is possible to omit faulty zones but this should 
only be used as a last resort if the building is to be left unoccupied. 

Master code cannot be deleted.  

Example:  Set panel, 

 

 

Limited User Code 

 

 

 

then: 

If no error tone heard, exit via normal route. 

Enter 

 followed by 

 Master User Code (factory set at 1 2 3 4) 

 

 

 

or:    

If error tone heard:  

 

 

 

 

Enter:   

 

 

Enter 

 to 

 

 

 

 

then; 

number(s) of zones to be omitted (1 to 8)  

   then:  

Entry / Exit timer will start again. 

Enter the new code twice, three tones will be heard on acceptance of each command, a 
single low tone indicates programming not accepted. 

   then: 

exit 

building by normal route. 

To delete a user code press the 

 key after 

 to 

 is entered. 

 

RINS137-7 RINS137-7 

Intelligent Security & Fire Ltd

Summary of Contents for STERLING 10

Page 1: ...MJOH 10 USER GUIDE ARM MODE A ARM MODE B ARM MODE C ARM MODE D TM 8 A B C D 2 1 3 4 SET 5 6 7 8 9 0 INSTALLER DETAILS TELEPHONE X X X X X X X X A B C D OR I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 2: ... the event log by entering A O symbol followed by 1 4 will be displayed There are two levels of user access to the system The Master Code Code 1 allows access to all user functions and programming features 1 Bell Fuse Fail 2 Auxiliary Fuse Fail 3 Telephone Line Fail 4 Mains AC Fail The User Codes Codes 2 to 6 allow arming disarming of the panel enabling and disabling of the door chime and viewing ...

Page 3: ... PTS button is pressed The numbers of any activated zones will be entered into the event log Zones programmed as Keyswitch zones when activated in walk test will not be entered in the event log Final Door Set Changing Master and Limited User Codes Set the panel in any of the above methods the panel will count down but will not set until the final exit door is opened then closed Master Code Enter f...

Page 4: ...used to turn off the chime facility Reading The Event Log Panel must be in day mode Enter The day led will flash and the most recent event stored in the log will be displayed If the up arrow key is pressed the previous log entry will be displayed Similarly if the down arrow key is pressed the next most recent entry will be displayed The event log may be scrolled backwards and forwards using the up...

Reviews: