![PYROMANIA GAS4160-B Feature Manual Download Page 8](http://html1.mh-extra.com/html/pyromania/gas4160-b/gas4160-b_feature-manual_1632721008.webp)
NSTALLATION INSTRUCTIONS
Continued
7
_________________________________________________________________________________________________
CONVERSION INSTRUCTIONS – PROPANE MODELS ONLY
(XTZOA SERIES AND XTZIA SERIES)
This appliance can be used with propane and natural gas. However, the appliance is adjusted and shipped for use with
propane gas. To convert to natural gas, use ONLY a natural gas conversion Kit: GAS1000.
1: Adjust the air shutter to the closed position (as shown at right with no light visible through the shutter) by loosening
the locking screw on the air-mixer and sliding the air shutter to the closed position and re-tightening the screw.
2: Remove the stainless steel flex-pipe from the orifice assembly and then the orifice assembly from the air mixer.
3: Remove the propane orifice from the orifice assembly and replace it with the natural gas orifice (3.73mm orifice).
4: Reinstall the orifice assembly and reattach the stainless steel flex-pipe. Make sure that it is tight.
5: Remove the propane hose/regulator from the bulkhead connection (located at the bottom of the fire table)
6: Install the natural gas supply hose onto the bulkhead fitting.
7: Place all markings provided with the kit onto the rating plate on the converted appliance.
8: Perform a leak testing of the converted appliance before operating the converted appliance (see the “
LEAK TEST
”
section of page 8 of the manual).
Natural gas fire tables are set-up to operate on natural gas only, at a pressure of seven inches of water column (7"
W.C.) Check with your gas utility for local gas pressure. Natural gas input rating is 50,000 Btu/hr (14.65kW/h).
9: After lighting, rotate the burner control knob counter clockwise to the “LOW” setting. Observe the flame and make
sure all burner ports are lit. The flame height should be no higher than 13 inches tall.
10: Adjust the flame to the desired height with the control knob.
AIR MIXER AND ORIFICE ASSEMBLY REMOVAL OF THE ORIFICE ASSEMBLY
I
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the
manufacturer’s instructions and all applicable codes and requirements of the Authority Having
Jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or
production of carbon monoxide may result causing property damage, personal injury or loss of
life. The qualified service agency is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of the converted appliance is
checked as specified in the manufacturer’s instructions supplied with the kit.