PYROMANIA GAS4160-B Feature Manual Download Page 1

 

 

PYROMANIA FIRE FEATURE MANUAL 

 
 
 

 
 

 
 

 

 

 

 

                                  

 

SHANGRI-LA 

FACTORY MODEL GAS4160-B (OAW) 

 
 

 

 

 

 

 

 

 
 
 
 
 

 

 
 

DANGER 

CARBON MONOXIDE HAZARD 

This appliance can produce carbon 
monoxide which has no odor. 
Using it in an enclosed space can kill you. 
Never use this appliance in an enclosed 

space such as a camper, tent, car or home

 

 

WARNING 

Do not store or use gasoline, or 

other flammable vapors and 

liquids,in the vicinity of this or any 

other appliance. 

An LP-cylinder not connected for 

use shall not be stored in vicinity 

of this or any other appliance. 

 

 

 

DANGER 

FIRE OR EXPLOSION HAZARD 

If you smell gas: 

 

Shut off gas to the appliance. 

 

Extinguish any open flame. 

 

If odor continues, leave the 

area immediately. 

 

After leaving the area, call 

your gas supplier or fire 

department. 

Failure to follow these instructions 

could result in fire or explosion, 

which could cause property 

damage, personal injury or death. 

INSTALLER: Leave this manual with the appliance. 
CONSUMER: Retain this manual for future reference. 

WARNING 

If the information in this manual is not followed exactly, 

a fire or explosion may result causing property damage, 

personal injury, or loss of life. 

 

WARNING: 

For Outdoor Use Only. 

Installation and service must be performed by a qualified 

installer, service agency, or the gas supplier. 

SM-5Y7704(CSA) 

Summary of Contents for GAS4160-B

Page 1: ...PLOSION HAZARD If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continues leave the area immediately After leaving the area call your gas supplier or fire department Fa...

Page 2: ...4 Connections liquid propane LPG 5 Connections natural gas NG 6 Conversion instructions propane to natural gas 7 Battery installation 8 Leak test 8 Lava rock installation 9 Operation instructions 10...

Page 3: ...burner and components carefully for any signs of damage or loose connections If any damage is found contact the retailer and report it immediately Tighten any loose connections and perform a leak tes...

Page 4: ...es with the standard for Quick Disconnect Devices for Gas Fuel Appliances ANSI Z21 41 CSA6 9 There MUST be a pressure regulator with a maximum output of pressure of 14 W C installed in line When an ap...

Page 5: ...round it clear and free from combustible materials Gasoline and other flammable vapors and liquids must be kept a minimum of 25 feet away and auxiliary propane tanks should be stored at a minimum of 1...

Page 6: ...ram A B Tighten down the screw on the side of the tank seat to secure the propane tank refer to diagram B C Place the propane tank a minimum of 60 152 4CM away from the fire feature refer to diagram C...

Page 7: ...d This appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal t...

Page 8: ...kit onto the rating plate on the converted appliance 8 Perform a leak testing of the converted appliance before operating the converted appliance see the LEAK TEST section of page 8 of the manual Natu...

Page 9: ...soap to one part water 2 Make sure the appliance control knob is in the OFF position 3 Open the gas supply to the fire table 4 Apply the leak testing solution by spraying it on joints of the gas deliv...

Page 10: ...bag into the burner in order to prevent damage to the fire table to prevent clogging the burner ports with dust and to prevent getting debris in the ignitor box Only place enough lava rock to cover t...

Page 11: ...se of the fire table because they are the two areas that gas would most likely accumulate in case of a leak If you smell gas do not try to light the appliance Immediately close the manual shut off val...

Page 12: ...ight is 8 to 13 USING A LONG MATCH OR BBQ LIGHTER 1 Make sure that the burner control knob is in the OFF position 2 Prior to lighting clear some lava rock away from the burner ring with a garden trowe...

Page 13: ...the hose assembly for excessive abrasion or wear The hose assembly must be replaced prior to the appliance being put into use if any evidence of damage is found The replacement hose assembly must be o...

Page 14: ...the setting of the thermocouple refer to diagram 2 and confirm the connection is tight refer to diagram 3 C The gas pressure is too low Have a gas technician do a pressure test on the supply line D A...

Page 15: ...orrectly or depleted Ensure that a fresh AA battery is installed Positive side facing outward toward the sparker cap B There is corrosion on the battery contacts Check contact at the bottom of the bat...

Page 16: ...de 4 Ground wire 5 Thermocouple 6 Ignitor cover 7 Air mixer 8 Air shutter 9 Orifice 2 16mm for propane 3 73mm for natural gas 10 Orifice holder 11 Natural gas fitting 12 Stainless steel flex pipe 13 B...