NSTALLATION INSTRUCTIONS
4
_____________________________________________________________
SITE LOCATION
This appliance is for outdoor use only and must be used only in a well ventilated space. It must not be used in an enclosed
area such as a house, garage or enclosed patio. Toxic carbon monoxide fumes can accumulate and cause asphyxiation.
Do not install this appliance under or near windows and vents that can be opened into your home.
Keep clear of trees or shrubs.
Maintain sufficient distance from any overhead combustible material such as a patio cover or cabana.
Do not install this appliance in an explosive environment. Keep the area around it clear and free from combustible
materials. Gasoline and other flammable vapors and liquids must be kept a minimum of 25 feet away and auxiliary
propane tanks should be stored at a minimum of 10 feet away.
VENTILATION REQUIREMENTS
Fresh air must be able to pass under this appliance to safeguard against residual gas accumulation. Failure to allow proper
ventilation may cause a fire or explosion.
If installing this appliance without the supplied (optional) 3” legs, it should be placed on a hard level surface that allows
proper ventilation through the ½” gap incorporated into the bottom. If the installation method blocks the incorporated
gap, then an alternative method for allowing ventilation would be required.
I
Required minimum clearances (to combustible materials):
Sides and back - 48 inches (122 cm). Top - 72 inches (183 cm).
VENTILATION GAP