background image

Page 43

Contact SegenSolar (PTY) Ltd | e: [email protected] | t: 08780 20663

Thank you

To recap on todays' webinar please visit our portal

Summary of Contents for PowerCube-H1

Page 1: ...Page 1 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 PYLONTECH Product Presentation ...

Page 2: ...Page 2 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 01 PRODUCT OVERVIEW 03 INSTALLATION 04 TROUBLE SHOOTING 02 APPLICATION CONFIGURATION ...

Page 3: ...Page 3 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 PRODUCT OVERVIEW 01 ...

Page 4: ...Page 4 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Table 1 Powercube H series product parameters 1 System parameter feature 95 95 ...

Page 5: ...Page 5 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Table 2 Powercube H series product parameters 2 Battery module parameter feature ...

Page 6: ...e market Pylon batteries posses A DoD 95 B Focused on ESS has more than 10 years manufacturing experience C Voltage output Max 1000V with 74 Ah module D Weight 32kG for a 3 6kWh module E Efficiency 96 F Safety IEC62619 CE UL 1973 proved G Life span more than 6000 cycles H Warranty 10yrs I Operation environment 5 95 humidity 0 50 ...

Page 7: ...Page 7 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 APPLICATION CONFIGURATION 02 ...

Page 8: ...Page 8 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Application ...

Page 9: ... e info segensolar co za t 08780 20663 Commercial Note For the PV battery sizing ratio there is no strict rules but guidance at 1 2 as min e g 1kW PV shall sizing 2kWh battery system as min capacity for back up and off grid application ...

Page 10: ...evel 0 5C constant H48074 Single rack 5 17 8 240 270 217 5 Max 80A 15s 6 21 3 288 324 261 7 24 9 336 378 304 5 8 28 4 384 432 348 9 32 0 432 486 391 5 10 35 5 480 540 435 11 39 1 528 594 478 5 12 42 6 576 648 522 Additional rack 13 46 2 624 702 565 5 14 49 7 672 756 609 15 53 3 720 810 652 5 16 56 8 768 864 696 17 60 4 816 918 739 5 18 63 9 864 972 783 Table 3 Powercube H48074 system configuration...

Page 11: ... 11 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Quotation items 1 Battery Module BMS H48074 varying amount depends on application 2 External Cable kits 3 Brackets Cabinets if necessary ...

Page 12: ...Page 12 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 INSTALLATION 03 ...

Page 13: ...ar PTY Ltd e info segensolar co za t 08780 20663 CHECKING LIST For battery module package One power cable Serial Connection one battery communication cable for each battery package Figure 1 PowerCube H2 battery module package ...

Page 14: ...o segensolar co za t 08780 20663 CHECKING LIST For BMS Controller connects to inverter One positive power cable orange to orange one communication cable and user manual for each Controller package Figure 2 PowerCube H2 battery module package ...

Page 15: ...t SegenSolar PTY Ltd e info segensolar co za t 08780 20663 External cable kits 1 Pair of power cables One positive power cable orange One negative power cable black Figure 6 Battery external cable kits CHECKING LIST ...

Page 16: ...tallation manual and make sure you have all the necessary tools required PLEASE CHECK THE FOLLOWING The ambient temperature is within the range of 0 C to 50 C Please DO NOT connect the batteries in parallel Do not connect battery with PV solar or AC power directly Cut off the grid power and make sure the battery is in the turned off mode Make sure the voltage of the battery system is in the PCS DC...

Page 17: ...Page 17 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Battery Module Front Interface Figure 3 H48050 front interface Installation ...

Page 18: ...Page 18 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Battery BMS Module SC0500 1000 100S Front Interface Figure 4 BMS module front interface Installation ...

Page 19: ...Page 19 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Battery 3rd Level Control Module MBMS Front Interface Figure 5 MBMS front interface Installation ...

Page 20: ...al of power cable should connect to the black terminal of the battery HV system s grounding is based on metal directly touch between the module s surface and rack s surface Please DO NOT connect the batteries in parallel Do not connect battery with PV solar or AC power directly Do not connect the battery system to the grid power before finishing cable connection and switching on the batteries ...

Page 21: ...Page 21 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Note The 1stPowerCube H1 H2 should be installed nearest to the MBMS Figure 6 H48074 system cable connection ...

Page 22: ...s and communication cables Turn on the 1st BMS Battery Control Modules of battery string The second BMS must be turned on after the first battery string s self check is successful Then turn on the battery strings on one by one from 1st BMS to the last BMS MBMS must be turned on after all battery strings self check finish ...

Page 23: ...Page 23 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 POWER ON Turn on the POWER SWITCH Figure 7 BMS power switch ...

Page 24: ...Page 24 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 POWER ON For off grid systems or emergency situations ...

Page 25: ...battery string s system will check itself Self check will be finish within 10sec If the BMS can t receive communication from upper equipment because of the communication is off the STATUS lamp will light red after 30sec That doesn t mean failure exists it means this battery string is ok while the external communication is off Figure 8 MBMS power switch ...

Page 26: ...e 26 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 POWER OFF Turn off the Power Switch of the MBMS If the ESS configures only single battery without MBMS then ignore this operation step ...

Page 27: ...solar co za t 08780 20663 POWER OFF Soft off the PCS through PCS s control panel Turn off the Power Switch of the BMS TIPS DO NOT turn off the Power Relay Switch during normal running condition only in emergency case it could be turned off directly ...

Page 28: ...ommunication Application Key features Installation Activation Force charge Solis Power Cube H1 H2 X1 X2 Force H1 H2 5 11 group 160 600 5k 6k 10k CAN On Off grid Yes Yes Wall mounting Atess 8 11 group 352 600 30k 50k 120k 150k CAN On Off grid Yes Yes Cabinet BME 8 10 group 384 480 20k 30k CAN On Off grid Yes Yes Cabinet Table 4 Powercube H2 compatible list ...

Page 29: ...er connection diagram CAN BAT inverter Pin1 Pin2 Pin3 Pin4 CAN H CAN H Pin5 CAN L CAN L Pin6 Pin7 Pin8 Comm Cable PINOUT MBMS ADD setting 100011 BMS ADD setting CAN Modbus Address dial bit 0 1 00000X 1 1 10000X 2 2 01000X 3 3 11000X 4 4 00100X 5 5 10100X 6 6 01100X Note that the last BMS s terminal resistance must set in 1 X 1 Suitable Breaker ...

Page 30: ...info segensolar co za t 08780 20663 Configuration Solis 1 Press Enter to Menu 2 Select Advanced Settings 3 Enter Password 0010 4 Select Battery Control 5 Select Battery Select 6 Select Pylon 7 Set Over discharge SOC 8 Set Force charge SOC ...

Page 31: ... H CAN H A Pin5 CAN L CAN L A Pin6 Pin7 Pin8 Comm Cable PINOUT MBMS ADD setting 100011 BMS ADD setting CAN Modbus Address dial bit 0 1 00000X 1 1 10000X 2 2 01000X 3 3 11000X 4 4 00100X 5 5 10100X 6 6 01100X Note that the last BMS s terminal resistance must set in 1 X 1 Figure 10 Pylontech batteries with Atess inverter connection diagram ...

Page 32: ...ct SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Parameters Configuration 1 Connect cables turn on power switch 2 Enter the password 1234 to start settings 3 Click Protect Parameter change the parameters ...

Page 33: ...Page 33 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Parameters Configuration 4 Change the parameters according to the application ...

Page 34: ...Page 34 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Parameters Configuration 5 If you are applying Peak shaving mode please change the Peak Valley and Flat time ...

Page 35: ...ontact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Function Mode Configuration 6 Click Sample Calibration window to start function configuration All the parameters depends on the system composition ...

Page 36: ...Page 36 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Function Mode Configuration 7 Mode selection depends on the customer s requirements ...

Page 37: ...Depends Battery cell number 15 x battery number Battery capacity 74 Battery charging overcurrent protection 80 Battery discharging overcurrent protection 80 Float charge voltage setting 3 550 Battery undervoltage warning 3 050 Battery undervoltage protect 2 900 Battery overvoltage warning 3 650 Battery starting voltage 2 600 Discharge cut off voltage 3 100 Note Other settings please refer to defau...

Page 38: ...er connection diagram RS485 BAT inverter Pin1 Pin2 Pin3 Pin4 485B Pin5 485A Pin6 Pin7 485A Pin8 485B Comm Cable PINOUT MBMS ADD setting 100011 BMS ADD setting CAN Modbus Address dial bit 0 1 00000X 1 1 10000X 2 2 01000X 3 3 11000X 4 4 00100X 5 5 10100X 6 6 01100X Note that the last BMS s terminal resistance must set in 1 X 1 Suitable Breaker ...

Page 39: ...etting Page 1 3 Charge Current Max 37A Float Voltage 53 25 x n n battery number V CV Voltage 53 25 x n V Page 2 3 Grid Available Max Bat Discharge 37A Grid Available Bat Discharge Off 43 5 x n V Bat Re dischg 48 75 x n V Page 3 3 Grid unavailable Bat Discharge Off 43 5 x n V Bat Re dischg 48 75 x n V ...

Page 40: ...Page 40 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 TROUBLE SHOOTING 04 ...

Page 41: ...d problems 1 Battery over voltage Solution Please check the inverter settings and the communication status between the inverter and the batteries 2 Battery voltages imbalance Solution Please disconnect the batteries in one group use a multimeter to test their terminal voltages Charge the low voltage batteries to a similar voltage value 3 BMS error Solution Please swap the BMS or use BatteryView to...

Page 42: ...fo segensolar co za t 08780 20663 Reference list 1 Pylon Technologies Co Ltd High Voltage Energy Storage System Datasheet 2 Pylon Technologies Co Ltd LFP Lithium Ion Energy Storage System PowerCube H1 H2 Operation Manual Version EU20PIHV1001 ...

Page 43: ...Page 43 Contact SegenSolar PTY Ltd e info segensolar co za t 08780 20663 Thank you To recap on todays webinar please visit our portal ...

Reviews: