background image

 

 

 
                                                                                                                                                                                                            19P1FL0801
 

 

 

1

 / 

12

 

1.

 

Safety Precautions 

 

Reminding 

1)

 

It is very important and necessary to read the user manual carefully (in the accessories) 
before  installing  or  using  battery.  Failure  to  do  so  or  to  follow  any  of  the  instructions  or 
warnings in this document can result in electrical shock, serious injury,  or death, or  can 
damage battery, potentially rendering it inoperable. 

2)

 

If the battery is stored for long time, it is required to charge them every six months, and the 
SOC should be no less than 90%; 

3)

 

Battery needs to be recharged within 12 hours, after fully discharged; 

4)

 

Do not expose cable outside; 

5)

 

All the battery terminals must be disconnected for maintenance; 

6)

 

Please contact the supplier within 24 hours if there is something abnormal. 

7)

 

Do not use cleaning solvents to clean battery; 

8)

 

Do not expose battery to flammable or harsh chemicals or vapors; 

9)

 

Do not paint any part of battery, include any internal or external components; 

10)

 

Do not connect battery with PV solar wiring directly; 

11)

 

The warranty claims are excluded for direct or indirect damage due to items above. 

12)

 

Any foreign object is prohibited to insert into any part of battery. 

 

 

Warning 

1.1 Before Connecting

 

1)

 

After  unpacking,  please  check  product  and  packing  list  first,  if  product  is  damaged or 
lack of parts, please contact with the local retailer; 

2)

 

Before installation, be sure to cut off the grid power and make sure the battery is in the 
turned-off mode;   

3)

 

Wiring must be correct, do not mistake the positive and negative cables, and ensure no 
short circuit with the external device;   

4)

 

It is prohibited to connect the battery and AC power directly;   

5)

 

The  embedded  BMS  in  the  battery  is  designed  for  48VDC,  please  DO  NOT  connect 
battery in series;   

6)

 

Battery system must be well ground and the resistance must be less than 1Ω;   

7)

 

Please  ensured  the  electrical  parameters  of  battery  system  are  compatible  to  related 
equipment;   

Summary of Contents for Force-L1

Page 1: ...Lithium Ion Phosphate Battery Force L1 Product Manual Information Version 2 2...

Page 2: ...ing the installation process Any confusion please contact Pylontech immediately for advice and clarification CONTENT 1 SAFETY PRECAUTIONS 1 1 1 Before Connecting 1 1 2 In Using 2 2 INTRODUCTION 3 2 1...

Page 3: ...s or vapors 9 Do not paint any part of battery include any internal or external components 10 Do not connect battery with PV solar wiring directly 11 The warranty claims are excluded for direct or ind...

Page 4: ...working with faulty or incompatible inverter 4 It is prohibited to disassemble the battery QC tab removed or damaged 5 In case of fire only dry powder fire extinguisher can be used liquid fire extingu...

Page 5: ...s 2 1 features The whole module is non toxic non polluting and environmentally friendly Cathode material is made from LiFePO4 with safety performance and long cycle life Battery management system BMS...

Page 6: ...19P1FL0801 4 12 2 2 Specifications 2 2 1 The parameter of system...

Page 7: ...ry System Charge Current Normal 100 Battery System Charge Current Max 15S 110 Battery System Discharge lower Voltage Vdc 44 5 Battery System Discharge Current Standard 100 Battery System Discharge Cur...

Page 8: ...Module Voltage Vdc 48 Battery Module Capacity Ah 74 Battery Module Serial Cell Quantity pcs 15 Battery Cell Voltage Vdc 3 2 Battery Cell Capacity AH 37 Dimension W D H mm 600 380 170 Weight kg 35 Oper...

Page 9: ...0048 100 Display Panel LED Button Short Press Display the LED panel for 20sec Long Press more than 5sec When status LED fast flash blue loss the button then it is chosen 115200 baud rate of RS485 When...

Page 10: ...address Battery Module Status Battery Module Status blue means working normally Orange means protection or failure Blue slow flashing Alarm exist but can work continue Blue lighting Normal Blue light...

Page 11: ...or short circuit must wait more than 30min then can turn on it again otherwise may cause the breaker damage Start Start function press more than 5sec until the buzzer rings to turn on controller Blac...

Page 12: ...ttery system and inverter CAN Communication Terminal RJ45 port follow CAN protocol for communication between battery system and inverter CAN Communication Terminal RJ45 port follow CAN protocol Link p...

Page 13: ...19P1FL0801 11 12 Definition of RJ45 Port Pin CAN RS485 RS232 TX CANH CANL GND RX RS485A RS485B Note Other Pin must be NULL if not may influence the communication of system...

Page 14: ...ntion 2 Fire NO WATER Only dry powder fire extinguisher can be used if possible move the battery pack to a safe area before it catches fire 3 Wet Batteries If the battery pack is wet or submerged in w...

Page 15: ...Pylon Technologies Co Ltd No 73 Lane 887 ZuChongzhi Road Zhangjiang Hi Tech Park Pudong Shanghai 201203 China T 86 21 51317699 F 86 21 51317698 E service pylontech com cn W www pylontech com cn...

Reviews: