                                                                                                                                                                                                            19PIFP0301 
 

 

 
This  manual  introduces  Force-L2  from  Pylontech.  Force-L2  is  a  48Vdc  Lithium-Ion  Phosphate 
Battery  storage  system.

 

Please  read  this  manual  before  you  install  the  battery  and  follow  the 

instruction  carefully  during  the  installation  process.  Any  confusion,  please  contact  Pylontech 
immediately for advice and clarification. 
 

CONTENT

 

1.

 

SAFETY PRECAUTIONS ..................................................................................................................... 1

 

1.1 Before Connecting .................................................................................................................... 

1.2 In Using ..................................................................................................................................... 

2. INTRODUCTION ...................................................................................................................................... 3

 

2.1 features: .................................................................................................................................... 3 
2.2 Specifications ............................................................................................................................ 4 
2.2.1 The parameter of system ....................................................................................................... 4 
2.2.2 Battery Module (FL4874M) .................................................................................................... 6 
2.2.3 Control Module FC0048M-100 (internal power supply) ........................................................ 7 
Definition of RJ45 Port Pin ........................................................................................................... 11 

3.

 

EMERGENCY SITUATIONS ............................................................................................................... 12

 

 

 

Summary of Contents for 48V148AH

Page 1: ...Manual Information Version 2 2 Pylon Technologies Co Ltd No 73 Lane 887 ZuChongzhi Road Zhangjiang Hi Tech Park Pudong Shanghai 201203 China Zip Code 201203 Tel 021 51317699 Fax 021 51317698 Email se...

Page 2: ...y during the installation process Any confusion please contact Pylontech immediately for advice and clarification CONTENT 1 SAFETY PRECAUTIONS 1 1 1 Before Connecting 1 1 2 In Using 2 2 INTRODUCTION 3...

Page 3: ...icals or vapors 9 Do not paint any part of battery include any internal or external components 10 Do not connect battery with PV solar wiring directly 11 The warranty claims are excluded for direct or...

Page 4: ...ries working with faulty or incompatible inverter 4 It is prohibited to disassemble the battery QC tab removed or damaged 5 In case of fire only dry powder fire extinguisher can be used liquid fire ex...

Page 5: ...ts 2 1 features The whole module is non toxic non polluting and environmentally friendly Cathode material is made from LiFePO4 with safety performance and long cycle life Battery management system BMS...

Page 6: ...19PIFP0301 4 13 2 2 Specifications 2 2 1 The parameter of system...

Page 7: ...rge Current Normal 75 100 100 Battery System Charge Current Max 15S 110 110 110 Battery System Discharge lower Voltage Vdc 44 5 Battery System Discharge Current Standard 30 45 60 Battery System Discha...

Page 8: ...Module Voltage Vdc 48 Battery Module Capacity Ah 74 Battery Module Serial Cell Quantity pcs 15 Battery Cell Voltage Vdc 3 2 Battery Cell Capacity AH 37 Dimension W D H mm 450 296 296 Weight kg 35 Ope...

Page 9: ...odule FC0048M 100 Display Panel LED Button Short Press Display the LED panel for 20sec Long Press more than 5sec When all LED flash blue loss the button then it is chosen 115200 baud rate of RS485 Whe...

Page 10: ...address Battery Module Status Battery Module Status blue means working normally Orange means protection or failure Blue slow flashing Alarm exist but can work continue Blue lighting Normal Blue light...

Page 11: ...off because of over current or short circuit must wait more than 30min then can turn on it again otherwise may cause the breaker damage Start Start function press more than 5sec until the buzzer rings...

Page 12: ...S485 Communication Terminal RJ45 port follow RS485 protocol for communication between battery system and inverter CAN Communication Terminal RJ45 port follow CAN protocol for communication between bat...

Page 13: ...J45 port follow RS232 protocol for manufacturer or professional engineer to debug or service Definition of RJ45 Port Pin CAN RS485 RS232 TX CANH CANL GND RX RS485A RS485B Note Other Pin must be NULL i...

Page 14: ...ntion 2 Fire NO WATER Only dry powder fire extinguisher can be used if possible move the battery pack to a safe area before it catches fire 3 Wet Batteries If the battery pack is wet or submerged in w...

Page 15: ...P0301 13 13 Pylon Technologies Co Ltd No 73 Lane 887 ZuChongzhi Road Zhangjiang Hi Tech Park Pudong Shanghai 201203 China T 86 21 51317699 F 86 21 51317698 E service pylontech com cn W www pylontech c...