In case the following situations, please deal with it according to the following methods, if 
it does not work, please contact distributor and inform the detailed failure. 

The wind 
blowing 
out,but the 
cooling/
heating
effect is
bad

The wind 
blowing 
out,but it
does not
refrigerate

Failure

Start-up 
failure

The air inlet or outlet of machine is blocked

The air inlet or outlet of machine is blocked

Compressor has three min tes protection

u

It doesn t reach the set time for start up

Mistakes in temperature setting

The air filter is blocked by dust

The doors or windows are open

Mistakes in temperature setting

The power switch is released 

The battery is exhausted

Power supply failure

The fuse is burnt

Causes

,

Wait for the recovery of power supply

Wait or eliminate the original setting

Remove the obstruction, then restart it

Set a proper temperature, see the 
methods of application

Close the doors and windows

Set a proper temperature

Remove the obstruction

Switch on the power 

Replace the battery

Clean the air filter

Replace the fuse 

Wait 

Methods of resolution

The normal protections of the air-conditioner

1.Compressor protection

The compressor will not restart within 3 minutes after stop operating

the heating operation just starts                               

frost dissolving operation   

operating under low temperature

Cold wind prevention (heat pump type )

Non-air-conditioner  trouble

In the heating mode, the indoor unit won t send wind or operate in low wind ,if the heat
exchanger of indoor unit has not reached the stipulated temperature in the following 
three states, so as to prevent the cold wind.

,

Frost dissolving operation (hot pump type )

 The fan of the indoor and outdoor unit will stop under frost dissolving operation.
 The time for frost dissolving varies in range of 4 to 10 minutes according to the out-

    door temperature and the frost condition.

 It is normal phenomenon that there may be steam coming out from the outdoor unit

    during the frost dissolving operation.

 

When the temperature is low and humidity is high outdoors, the heat exchanger of 
outdoor unit may frost, which may decrease the heating capacity. In such case, the air-
conditioner will stop the heating operation and convert to automatic frost dissolving,
and then resume heating after the frost dissolving finishes.

,

Summary of Contents for ACP1

Page 1: ...d be carried out by licenced electrician In order to use it safely correctly and efficiently please read the instructions carefully and keep the instructions for reference in the future Thank you for you purchasing our air conditioner Make sure of grounding connection of the air conditioner Model ACP1 ACP15 ACP25 ...

Page 2: ...n 10 4 5 10 10 10 4 Outdoor Unit Remote controller usage Hand control operation Checking before usage Optimal operation Failure type and methods of resolution Non air conditioner trouble Cleaning Maintenance Guide of customer Installation position Items of attention 6 7 9 9 3 Working condition Safety rules ...

Page 3: ...ng capacity W Circulating wind quantity Heating capacity W m h 3 6 35 0 6 9 52 0 6 30 40 50 780 820 3 5 3 7 1300 6 2 2750 420 2500 ACP1 ACP15 30 40 51 960 1050 4 6 4 9 1500 6 9 3520 520 3200 Suitable room area m 2 12 20 14 22 12 7 0 7 F3 15AL 250V 3 15A Type of the fuse Note 1 Specifications are standard values calculated based on rated operating conditions they will vary in difference working con...

Page 4: ...anel Horizontal airflow directionvane Vertical airflow directionvane inner Air filter Drain pipe Pipe and Drainpipe Cut off valve Outlet cover Note Figure 1 is for illustration only Please refer to product gift box for actual products appearance 11 12 Outdoor Unit Parts Description 2 1 Fig 1 Pipe protection ring ...

Page 5: ...ion button to make it stop Press and hold the button for one it starts to operate second In case the remote controller does not work press the forced operation button which is an automatic The airflow direction is adjusted automatically operation 3 Cooling Heating Indoor Outdoor Indoor Outdoor Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum DB WB DB WB DB WB DB WB DB WB DB WB DB WB...

Page 6: ...outlet andinlet are notblocked The earth wireis connected safelyand reliably The filter netis properly fixed If the unitis not inuse for along time pleaseclean the filternet before startingthe see Maintenance for how tooperate air conditioner Checking before usage Set the suitable temperature especially when there are old people children and patients in the room In the case the air conditioner occ...

Page 7: ...o avoid incident Liquid detergent or corrosive detergent should not be used for cleaning the machine and sprinkle water or other liquid onto it Otherwise it may result in damages on the plastic components of the case even electric shock ÉÁ µç ÉÁ µç Set the suitable temperature for a comfortable environment Don t make the room too cold or too hot During the cooling operation don t allow the sunligh...

Page 8: ...our hand orstick shaped objects into the airoutlet of theindoor and outdoor unit otherwise therotating fan athigh speed may cause injuryto you Danger Danger Do not pull out the power cord The damage of power cord will cause serious electric shock Do not operatewith wet handsor in damp environment it will cause electric shock Electric shock In case the following situation please immediately stop th...

Page 9: ...ait Methods of resolution The normal protections of the air conditioner 1 Compressor protection The compressor will not restart within 3 minutes after stop operating the heating operation just starts frost dissolving operation operating under low temperature Cold wind prevention heat pump type Non air conditioner trouble In the heating mode the indoor unit won t send wind or operate in low wind if...

Page 10: ...ts maximum ventilationposition i e close to the positionnormal to thehorizontal direction and choose to improve thedew phenomenon high When the air conditioner is used the first timeafter being leftunused for along time the dust inside theindoor unit willbe blown out The s ell which absorbedfrom room furniture clothing or cigaretteemanates during the air conditioner is operating m When the indooru...

Page 11: ...lean the air filter 1 Raise up the front panel of indoor unit until it suddenly stops then raise up the protruded part of air filter and pull it out downwards Don t use dedusting products by chemicals or place close to the machine 3 The panel of indoor machine may be taken off Dry it after cleaning with wet cloth 2 If the indoor unit is very dirty please wipe with wet cloth dipped by cold water Do...

Page 12: ...capacity should be more than 1 5 times of the maximum current Must use special circuit and efficient grounding socket matching with the plug of air conditioner The wiring must be done by qualified electrician according to the electrical safety requirements The air conditioner must be well grou ded the switch of the main power of air conditioner must be reliably grounded n Don t pull the power supp...

Page 13: ...15998003885 T01032 ...

Reviews: