www.proindecsa.com / [email protected]
OPERATING AND MAINTENANCE MANUAL
PYD SERIES SOLAR INVERTER
36
6. PERMANENT MAGNET / ASYNCHRONOUS PARAMETERS
Parameter
Explanation
Configurations
Configuration
factory
settings
Value to
be
adjusted
b0-00
Engine selection
0 Asynchronous
2 Perm. magnet motor
2
According to
model
b0-01
Engine control mode
0: Magnets
2: Asynchronous
2
According to
model
b0-02
Command source
0 Display keypad
1 Terminal control
2 Communication control
0
According to
model
b0-12
Engine frequency
0 0hz, maximum
Frequency b0-13
50
According to
model
b0-13
Maximum frequency
50-3000hz
50
According to
model
b0-15
Limit frequency
Min frequency ~
Max frequency
50
According to
model
b0-17
Lower frequency limit
0.00 Hz ~upper frequency
limit (b0-15)
0
According to
model
b0-18
Motor direction of rotation
0 Forward
1 Inverted
0
0
b0-21
Acceleration time
0~65000s
10
According to
model
b0-22
Deceleration time
0~65000s
10
According to
model
d0-00
Motor power
0.1kw~1000.0KW
Depending on
model
According to
model
d0-01
Motor voltage
1~2000V
Depending on
model
According to
model
d0-02
Motor rated current
0.1~6553.5A
Depending on
model
According to
model
d0-03
Motor frequency
0 - 01~maximum frequency
50
According to
model
d0-04
Motor RPM
1~65535RPM
1500
According to
model
d0-30
Autotunning (magnets only)
11 Motor+pump
12 Motor
00
According to
model