Information on version

The PX284 lamp is available in several versions that differ in the angle of 

the lenses used and the color of the LEDs.

  Below there is a description of designation of the PX284 models and 

their explanation:
PX284 – XX – YYY – ZZ

XX – 

 

 lens angle

 

 :  

YYY

    – 

   color

 

  LEDs:

 

 

ZZ

    – 

   lamp housing version:

 

 

10 – 10°

927 – CRI 90, 2700K

SH – with a handle

25 – 25°

930 – CRI 90, 3000K

40 – 40°

940 – CRI 90, 4000K
950 – CRI 90, 5000K
957 – CRI 90, 5700K

Example of marking for a lamp with a lens angle of 25°, LEDs 3000K and with 
a handle:

PX284-25-930-SH

The housing, compliant with the IP68 standard, allows the device to be 

used in underwater applications, for example in fountains, swimming pools, 
as well as in places exposed to adverse weather conditions.

6

Summary of Contents for PxAqua PX284

Page 1: ...PX284 PxAqua 3 SH 12V User manual ...

Page 2: ...nection scheme 7 5 Dimensions 8 6 Technical data 9 Manufacturer reserves the right to make modifications in order to improve device operation PXM Marek Żupnik sp k Podłęże 654 32 003 Podłęże BDO register number 000005972 tel 48 12 385 83 06 mail info pxm pl www pxm pl Rev 1 2 23 03 2021 2 ...

Page 3: ...vailable in white color in different color temperatures 2700K 3000K 4000K 5000K 5700K The PX284 may be provided with optics beam angles of 10 22 standard or 40 The casing is made of stainless steel 316L The device is supplied with 2m cable The PX284 can only be powered supplied from12V DC It can be powered with a voltage LED driver or voltage power supply It also can be dimmed when using voltage L...

Page 4: ...urns Warning Read the instruction manual Caution Do not look at the LEDs LEDs can cause damage or eye irritation Do not look at the light source with any optical devices that focus the light rays Light is harmful to unprotected eyes can cause irritation eye damage or even loss of eyesight While working outdoors in normal conditions the housing unit can heat up to 65 C Make sure that accidental con...

Page 5: ...h technical data 3 All the conductors should be protected against mechanical and thermal damage 4 In the event of damaging any conductor it should be replaced with a conductor of the same technical data 5 All repairs and connections of outputs can only be made with cut off power supply 6 Do not connect to the power supply to device with visible damage 7 All sudden shocks particularly dropping shou...

Page 6: ... YYY color LEDs ZZ lamp housing version 10 10 927 CRI 90 2700K SH with a handle 25 25 930 CRI 90 3000K 40 40 940 CRI 90 4000K 950 CRI 90 5000K 957 CRI 90 5700K Example of marking for a lamp with a lens angle of 25 LEDs 3000K and with a handle PX284 25 930 SH The housing compliant with the IP68 standard allows the device to be used in underwater applications for example in fountains swimming pools ...

Page 7: ...with voltage power supply 7 LED driver power supply 12V DC V V L N The cables should be connected in the correct color order For example the red wire with the terminal and the black wire with the R B G terminal The number of LED lamps depends on the driver and power supply voltage power supply 12V DC V V L N ...

Page 8: ...5 Dimensions 8 80 Ø56 33 ...

Page 9: ...rrent consumption 350mA IP rate IP68 housing stainless steel 316L CRI 80 beam angles 10 22 40 LED colors 2700K 3000K 4000K 5000K 5700K brightness 22 distance 1m 1120lx weight 0 5kg dimensions diameter 56mm height 33mm height with the handle 80mm available on request 9 ...

Page 10: ...000 2018 EN 60598 1 2015 EN 62471 2008 EN 61000 4 2 2009 EN IEC 61000 6 1 2019 EN 61000 6 3 2007 and meets the essential requirements of the following directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Text with EEA relevance 2014 30 UE DIRECTIVE OF THE EUR...