PXM PX206 Manual Download Page 4

3. COUPLINGS AND CONTROL ELEMENTS DESCRIPTION

2

Output control LED’s

DO NOT OVERLOAD!

8 CHANNELS

LOAD CONNECTION

DMX signal 

presence LED

Control buttons

+12     24V DC / 8A max.

LOAD 12 - 24V DC, 1A max

Caution!

To evenly load each of power supply dedicated pins 
connect power supply conductors (12 - 24V DC and 
GND one) to all suitable device pins - according to 
diagram.

GND

POWER SUPPLY

NO CONNECTION

NO CONNECTION

DMX-512 INPUT

DMX-512 OUTPUT

Caution!

Do not connect DMX input and 
output  pins  in  parallel  mode. 
Details  -  section  4  of  the 
manual.

LOAD 12 - 24V DC, 1A max

LOAD 12 - 24V DC, 1A max

LOAD 12 - 24V DC, 1A max

LOAD 12 - 24V DC, 1A max

LOAD 12 - 24V DC, 1A max

LOAD 12 - 24V DC, 1A max

LOAD 12 - 24V DC, 1A max

+

+

+

+

+

+

8x1A OC

Summary of Contents for PX206

Page 1: ...Electronic Switch 8x1 A OC PX206 MANUAL R...

Page 2: ...on or exclusion DMX value level 6 3 PX206 reaction to DMX signal interruption 7 Moving around the PX206 menu 8 Dimensions 9 Technical specification 1 1 2 3 3 3 4 4 4 5 5 5 CONTENTS Manufacturer reserv...

Page 3: ...ONDITIONS Electronic switch PX206 is powered with safe voltage 12 24V however during its installation and use the following rules must be strictly observed 1 The device may only be connected to 12 24V...

Page 4: ...pins connect power supply conductors 12 24V DC and GND one to all suitable device pins according to diagram GND POWER SUPPLY NO CONNECTION NO CONNECTION DMX 512 INPUT DMX 512 OUTPUT Caution Do not co...

Page 5: ...st DMX chain receiver there should be terminator resistor 110 Ohm mounted between DMX and DMX pins of DMX OUTsection CORRECT 110 Ohm WRONG 5 DISPLAYED MESSAGES MEANING DMX address setting for all chan...

Page 6: ...R DMX channel address you can set in two ways group and individuall addressing 1 Group addressing NOTICE Group adressingn automatically overwrites the previous individual addressing 2 Individual addre...

Page 7: ...A max as above control input output channels number each output load power supply current consumption all outputs OFF dimensions 8 DIMENSIONS mm 85 68 70 85 7 MOVING AROUND THE PX206 MENU 1 ENTER subm...

Page 8: ...res that the product Name of product Type answers the following product specifications EMC Additional informations Krak w 01 04 2008 DECLARATION OF CONFORMITY according to guide lines 89 336 EWG stage...