On
– screen saver activation
oFF
– screen saver deactivation
5.12 Temperature
The PX163+ was equipped with the possibility to check the temperature
inside the device. If the temperature exceeds 70°C, there is a linear limitation
of the device power until the exits will be switched off completely when the
temperature reaches 90°C. Additionally, the blinking message
Hot
in the main
menu will inform about the increased temperature.
70
(°C)
Power
100%
90
ENTER