Aby aktywować funkcję wygaszania podświetlenia należy:

1. Ustawić funkcję 

SCr  

i zatwierdzić wybór klawiszem 

enter

.

2. Za pomocą przycisków 

next

 lub 

previous

 zmienić wartość na "on" i zatwierdzić 

wybór klawiszem 

enter

.

Analogicznie  należy  postępować  w  celu  wyłączenia  tej  funkcji,  lecz  wówczas 

wybierając opcję "oFF".

14. BRIGHTNESS CONTROL FREQUENCY

1

2

ENTER

The "Frq" option allows to set the base frequency control for LEDs. This feature is especially 
useful in applications for the television industry. Thanks to use of "flicker free" technology it allows 
to avoid unpleasant flicker effect caused by lack of proper synchronization between signal and 
LEDs. 
The user can choose the frequency in range from 366 Hz to 1.5 kHz, which can be smoothly 
change using 

previous

 and 

next  

buttons to  set expected value.

The frequency in the upper range (e.g. value 1.50 = 1.5 kHz) allows to avoid flicker effect visible 
cameras.

To set the selected frequency range:

1. Set the 

Frq 

feature.

2. Use 

next

 or 

previous

 buttons to set the selected value.

ENTER

NEXT

2x

15. DISPLAY BLANKING

The device is equipped with the ability to disable backlight of display and operating LED of DMX 
signal status. This option enables the "SCr" menu. When it is activated, display and LED will 
switch off after 25 seconds (when no one in the same time will not press of any buttons of the 
PX305). Of course, the device continues to work without interfering with the other set parameters. 
To restore the backlight, use any button.

1

2

ENTER

NEXT

3x

NEXT

To activate the backlight blanking function follow those steps:

1. Set the 

SCr

and confirm by pressing enter.

2. Using the next or previous buttons change value to "on" and confirm with 

enter button.

Similarly, you must follow in order to disable this feature, but then instead 

of "on” in second step, by selecting "oFF".

-

NEXT

ENTER

In  case  of  not  connecting  to  the  PX305  any  temperature  sensor  and  the  simultaneous 

activation of the limit temperature (after setting           option in  the submenu           ) the 

driver displays a message             you that there is no temperature sensor. This information 

appears in the main menu instead of starting address DMX channel, and in the same time 

connected to outputs of the PX307 LEDs are turned off.

To disable this message, connect the temperature sensor or disable the temperature limit feature.

13. Er0 ERROR MESSAGE

Summary of Contents for PiXiMo 3350

Page 1: ...MANUAL LED Driver 3 x 350 mA 24V DC PX305 R PiXiMo 3350...

Page 2: ...12 Temperature limitations 13 Er0 error message 14 Brightness control frequency 15 Display blanking 16 Smooth 17 Default settings and memory error Err 18 Programming 19 Connection scheme 20 Dimension...

Page 3: ...current carrying capacity enable activating large quantities of LEDs PX305 can be controlled by the DMX signal or it can work independently In this operation mode the user has access to a fully progr...

Page 4: ...interruption MASTER SLAVE mode settings operation in BRIGHTNESS COLOUR mode operation in RGB mode turning all the outputs on at 100 setting the parameters for all channels concurrently 1 DMX 512 input...

Page 5: ...our setting during scene programming screen saver and DMX signal LED blanking turning ON OFF of MASTER mode setting the address of the first channel program no 17 memory error message restore default...

Page 6: ...e on enter the C d menu Press enter button to set a Con option on the display To choose the number of DMX channels to be sent from PX307 You need to enter the Chn menu ENTER ENTER ENTER NEXT NEXT You...

Page 7: ...e on oFF turns the white balance feature off PX305 can operate in HSL 4 channel 3 channel and 2 channel mode The HSL mode operates on 3 channels each channel regulates in turn hue saturation and light...

Page 8: ...ty to control the parameter of the selected mode EFF mode effect settings CHANNEL1 RED CHANNEL 2 GREEN CHANNEL 3 BLUE CHANNEL 5 SPEED CHANNEL 6 FADE CHANNEL 7 BRIGHTN x x x x x x x x x x x x x x x x x...

Page 9: ...of range of selected mode For example when you select mode only address 1 and 2 can be individually assign the selected value For the rest from to the unit displays a message that the address is out o...

Page 10: ...k 2 krok 3 krok 4 P11 P12 P13 P14 P15 P16 P17 P18 0 0 0 255 255 127 127 127 127 127 127 127 127 127 127 127 127 0 0 255 0 0 255 0 0 255 0 255 0 255 0 0 255 0 0 255 0 0 255 0 255 0 0 255 0 255 0 255 25...

Page 11: ...4 Similarly you can change the default values for temperature of activation 60 C by default and the maximum temperature 90 C by default function ENTER NEXT 4x 11 ENTER NEXT NEXT NEXT NEXT NEXT NEXT E...

Page 12: ...tivated display and LED will switch off after 25 seconds when no one in the same time will not press of any buttons of the PX305 Of course the device continues to work without interfering with the oth...

Page 13: ...ackets of DMX signal for selected option or within the time interval set in submenu _ NEXT NEXT ENTER Smoothing function in some cases may slightly slow down the rate of the reaction of end devices e...

Page 14: ...ver operating mode RGB 3b 3 byte master mode off number of sent DMX channels 128 white balance off no signal operating mode Program 1 smoothing function smooth off temperature limitation off 14 Err me...

Page 15: ...scrolls the menu backwards and decreases the parameters ENTER ENTER NEXT ENTER ENTER ENTER ENTER ENTER ENTER PREVIOUS NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT ENTER ENTER ENTER NEXT ENTER NEX...

Page 16: ...For DMX signal connection use the shielded conductors only CAUTION In case of voltage loss on one of the modules in a chain this one and the subsequent modules will not respond to a DMX signal Caution...

Page 17: ...15 kg 175 mm 44 mm 21 mm for 4 6 LEDs channel for DMX channels power supply current consumption no load current consumption output channels number outputs load capacity control accuracy programmable...

Page 18: ...X connectors mgr in Marek upnik Name of producer Address of producer declares that the product Name of product Type answers the following product specifications LVD EMC Additional information Krak w 2...

Reviews: