3. Safety rules

WARNING:
Despite of all the precautions adopted when designing the equipment, there are 
some risk elements that arise during operation and servicing.

HOT SURFACES
The temperature of the pump surfaces may exceed 80°C.
Install the pump in a protected area accessible only by authorized personnel, to prevent 
possible personal injures due to contact with hot surfaces. 
The pump can be placed inside other machines by adopting the necessary safeguards. 
Before carrying out any maintenance on the pump, be sure the pump is cold.

HAZARD CAUSED BY VACUUM
Any contact with parts under vacuum can cause injuries. 
Avoid any contact with the pump inlet port during the pump operation. Introduce air in 
the inlet circuit before every operation cycle.

FOR A SAFE MAINTENANCE
All maintenance operations must be carried out with the pump idle, disconnected from 
the electrical supply, with the pump  cold, vented to atmospheric pressure. Prevent 
unexpected start-up (e.g. block the power switch with a personal lock).

ELECTRIC SAFETY 
Some components of the electric equipment are electrically charged during operation. 
Any contact may cause serious injuries to persons or objects.
Connection and control of the electric system must be carried out by skilled personnel 
only.
The electrical equipment must comply with the EN 60204-1 standard and with any other 
law in force in the Country of use.
Besides, electrical equipment must comply with EN 61000-6-4 and EN 61000-6-2 
standards concerning electromagnetic compatibility and electromagnetic immunity 
for  industrial environment.

FIRE HAZARD
WARNING!  The use of the pump in situations unforeseen or not recommended by this 
manual, as well as lack of correct maintenance, may create high risks for overheating 
or fire. 
In case of a fire do not use water to extinguish but use a powder CO

2

  extinguisher or 

other means compatible with the electrical equipment and lubricating oil. 

Summary of Contents for DRY 100

Page 1: ...DRY 100 DRY 250 DRY 300 Claw vacuum pumps Operating and maintenance instructions EN TRANSLATION Publication Number LI 2078 05 April 2021...

Page 2: ...operation page 7 5 1 Location page 7 5 2 Electric connection page 7 5 3 Connection to the machine page 8 5 4 Discharge air pipe line installation page 8 5 5 Commissioning page 8 5 6 Tips for use page...

Page 3: ...es place The suggestions given to the staff engaged in the installation and servicing assumes that the personnel is expert and prepared in facing any problem of servicing both mechanical and electrica...

Page 4: ...nnectedtothelowershaftbymeansofacoupling 2 2 Expected use ThepumpsoftheDRYserieshavebeendesignedtohandleairandsmallquantityofwater vapour They are suitable for the evacuation of closed systems or for...

Page 5: ...th the pump idle disconnected from the electrical supply with the pump cold vented to atmospheric pressure Prevent unexpected start up e g block the power switch with a personal lock ELECTRIC SAFETY S...

Page 6: ...eck that the packing is intact or if is shows signs of damages occurred during transportation If there is no damage proceed to the unpacking and check further the machine In case damages are found inf...

Page 7: ...patibility emissionstandardandimmunityforindustrial environments Check the main voltage and frequency in use to correspond to the data stamped on the motor name plate The electric motor must be protec...

Page 8: ...pipes with the same diameter as the tank discharge port with a maximum length of 15 m For longer pipes increase pipe diameter Pipe weights must not rest on the pump In the final length use flexible p...

Page 9: ...Change the oil every 5000 Rotant VF805 10000 Rotant VF 315 hours of operation draining the exhausted oil through the discharge ports 3 Use a oil ISO VG 150 When changing the oil also check the couplin...

Page 10: ...th the pump and advise the risks involved in handling if any Drain the lubricant from the pump prior to shipping the pump back 10 Disposal Meaning of the WEEE logo found in labels The following symbol...

Page 11: ...PVR Srl HEADQUARTERS Via Santa Vecchia 107 23868 Valmadrera LC Italy T 39 0341 1918 51 F 39 0341 1918 599 info pvr it www pvr it LOCAL UNIT Via IV Novembre 104F 23868 Valmadrera LC Italy...

Reviews: