PVG Heator SRE 104 C Operating Manual Download Page 8

+

F

 

USING THE TIMER

The timer allows you to switch on the heater automatically at a preset time. 
In order to switch on the timer, the correct time must have been set

 (refer to 

Section C)

 and the heater should be off. Follow the procedure below:

 Press the   button 

L

 and then the TIMER key 

O

 immediately after that.  

  The TIMER lamp 

Q

 and the 4-digit 

K

 will start blinking.

 Use the adjustment keys 

N

 to set the time at which the heater must ignite.  

  Use the key on the left (

N

hour) to set the hours and the key on the right  

 (

M

min.) to set the minutes (interval of 5 minutes)

.

3

  After approximately 10 seconds the 4-digit will show CLOCK again and the 

  TIMER lamp 

Q

 will light up, indicating that the timer function has been 

 

activated (Fig. G).

The timer will ensure that the room will have been heated to approximately  

  the required temperature at the set time.

When you want to switch off the heater and ignite it again with the timer, all 

you have to do is press the TIMER key 

(refer to Section G).

Press the   button 

L

 once to clear the timer setting.

SWITCHING OFF THE HEATER

There are two ways to switch off the heater. 

 Press the   button 

L

.  The  information  display  will  show  the  CLOCK 

 

  signal. Within approximately one minute the flame will have extinguished. 

2  

Press the TIMER key 

O

, when you want to switch off the heater and ignite it  

  again with the timer the next time. This not only switches off the heater, but  

 

it also activates the timer function. You can change the required time with  

 

the adjustment keys 

N

 

(refer to Section F).

THE INFORMATION DISPLAY

The information display 

K

 not only serves as an indicator of the (set) time and 

temperature (

sections C, E, and F

), it also indicates any malfunctioning of the 

heater. The code on the information display tells you what is the matter:

CODE 

INFORMATION 

WHAT TO DO

e -   0

 

Temperature within the heater too high. 

Cool-down and re-ignite.

f -   0

 

Power interrupted. 

Re-ignite the heater.

e -   1

 

Faulty thermostat. 

Contact your dealer.

f -   1

 

Faulty burner thermistor. 

Contact your dealer.

e -   2

 

Starting problems. 

Contact your dealer.

4

57

G: The TIMER indicator 

light indicates that the 

timer function has been 

switched on.

In case of any 

malfunctioning the 
information display 

will tell you what is the 

matter.

Summary of Contents for Heator SRE 104 C

Page 1: ...u 1 MANUEL D UTILISATION GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO KÄYTTÖOHJE OPERATING MANUAL ISTRUZIONI D USO BRUKSANVISNING GEBRUIKSAANWIJZING INSTRUKCJA OBSŁUGI BRUKSANVISNING 2 12 22 32 42 52 62 72 82 92 102 ...

Page 2: ...tif d allumage Débit calorifique Efficacité des dispositifs de sécurité Stabilité Contrôle de la teneur en NOx dans les produits de combustion Contrôle de la qualité de la combustion absence de CO Endurance Intermittence CONSEILS D UTILISATION ET D ENTRETIEN Se reporter à la notice jointe à l appareil et à la plaque de sécurité sur l appareil Référence et numéro de lot ou de série de l article se ...

Page 3: ...ections for Use first to ensure maximum lifetime for your heater Your heater comes with a 24 month manufacturer s warranty on all defects in materials or workmanship We wish you a warm and comfortable time with your heater Yours sincerely PVG Holding b v Customer Service Department 1 READ THE DIRECTIONS FOR USE FIRST 2 IN CASE OF ANY DOUBT CONTACT YOUR DEALER 3 BEFORE YOU START READING FOLD OUT TH...

Page 4: ...or Zibro Bio as a heating fuel assures you that you have a good quality fuel Before changing brands and or types of fuel make sure that the mobile heater first completely empties all of the remaining fuel inside the heater MAIN COMPONENTS Front plate Grid Base plate Lid for removable tank Operation panel Removable tank Fuel gauge removable tank Vent filter Thermostat Plug cord Information display ...

Page 5: ...heater was designed to operate exclusively on fuel for liquid fuel operated mobile heaters in accordance with the Decrees of 08 01 1998 and 18 07 2002 The use of other fuels is forbidden Ask your dealer or check our website for the addresses of our retailers The liquid fuel operated mobile heater is intended as an extra heater and not as a continuous source of heat Especially for United Kingdom On...

Page 6: ...n a suitable place since there can always be some spillage Follow the procedure below 1 Make sure that the heater is switched off 2 Open the upper lid and lift the removable tank out of the heater Fig B Note Some drops may leak from the tank Put down the removable tank cap pointing upwards handle on floor Fig C and screw off the fuel cap 3 Fill the removable tank using a fuel pump refer to fuel pu...

Page 7: ...ill start blinking indicating that the ignition procedure has started This will take a short while Once the heater is burning the POWER lamp will remain lit red The information display K will show two numbers The light next to them indicates that these numbers refer to the temperatures Fig F The actual room temperature is indicated below ROOM while the temperature setting is indicated below SET Th...

Page 8: ... clear the timer setting G SWITCHING OFF THE HEATER There are two ways to switch off the heater 1 Press the button L The information display will show the CLOCK signal Within approximately one minute the flame will have extinguished 2 Press the TIMER key O when you want to switch off the heater and ignite it again with the timer the next time This not only switches off the heater but it also activ...

Page 9: ...the burner is clean again the heater will automatically switch back to the highest setting again I CHILDPROOF LOCK The childproof lock can be used to prevent children accidentally changing the heater settings When the heater is burning and the childproof lock is on the heater can only be switched off Other functions are blocked then If the heater has already been switched off the childproof lock a...

Page 10: ...inst a hard surface Never clean it with water 3 Reinstall the fuel filter into the heater We recommend that you remove dust and stains from time to time with a damp cloth because otherwise these may cause stains that are hard to remove Do not remove any heater components yourself Always contact your dealer for repairs When the power cord is damaged it may only be replaced by an authorised fitter U...

Page 11: ... Fuel consumption l hr 0 313 AC 50 Hz Electrical consumption Fuel consumption g hr 250 igniter 320 W Burning time per tank hr 17 3 continuous 13 W Capacity removable tank litres 5 4 Fuse rating 250V 5A Weight kg 8 0 Monitoring of the quality of ventilation air renewal Direct measurement of the CO2 level NDIR CO2 sensor P At maximum setting Specified values are indicative P WARRANTY PROVISIONS Your...

Page 12: ...ng or still hot 3 Position the front of the heater at a distance of minimum 1 5 metres from walls curtains and furniture 4 Do not use the heater in dusty rooms You will not have optimum burning in such rooms Do not use the heater in the immediate surrounding of a bath a shower or a swimmingpool 5 Switch off the heater before you leave or go sleeping Unplug the heater as well when you go away for a...

Page 13: ...E 101 C Stover SRE 102 C Tectro SRE 103 C Heator SRE 104 C Toyoset SRE 105 C 3 Sous réserve de modification 2 Ändrungen vorbehalten 6 Ændringer forbeholdes 5 Nos reservamos el derecho de hacer modificaciones 4 Subject to modifications Sogetti a modifiche 1 Wijzigingen voorbehouden O ...

Page 14: ...ww pvg eu Per informazioni e in caso di problemi visitate il sito Web www pvg eu oppure contattate il Centro Assistenza Clienti per conoscere il numero di telefono consultate www pvg eu Hvis du trenger informasjon eller hvis du har et problem med produktet kan du gå til nettsidene www pvg eu Alternativt kan du kontakte med PVG forbrukertjeneste telefonnummeret i www pvg eu Als u informatie nodig h...

Reviews: