SB300 PVA
2.
Turn the stroke adjust (9) counterclockwise for two full turns.
Figure 2: Turn the Stroke Adjust Two Full Turns
3.
Operate the valve at this stroke adjust (9) setting. Adjust as necessary for your
application.
NOTE: Turn the stroke adjust counterclockwise to increase snuff back and turn
the stroke adjust clockwise to decrease snuff back.
4.
If you cannot get the necessary results, turn the stroke adjust counterclockwise
until it is fully loosened. Some applications work best this way. Decrease the
snuff back as necessary.
Figure 3: Stroke Adjust Fully Loosened
Shutdown
4.3
1.
Release the pressure in the system, refer to the workcell manual.
2.
Open the valve and let any material dispense until the system pressure is close
to zero.
REVISION A (2014)