Nixie Tube Clock ‘Nixie QTC-Four’
Issue 1 (1 December 2019)
www.pvelectronics.co.uk
- 13 -
4.3
High Voltage Generator components.
Socket for IC2
R1, R2 (4.7 KΩ)
R3 (390 KΩ)
C3 (1uF)
C4 (220uF)
Q1 (IRFD220)
L2 (100uH Inductor)
D5 (UF4004)
Take care that the notched end of the IC socket is at the end
shown. However, if you find you soldered it with the wrong
orientation, do not try to remove it. It is perfectly fine with the
notch at the wrong end, just be sure to place the IC in the socket
with the IC’s notch in the correct position.
Also the MOSFET needs to be placed with the two joined pins at the
position shown below.
C3 and C4 are polarised – the longer lead goes in the hole marked
+