SECTION IV.  INSTALLATION STEPS 

  All plumbing should be done in accordance with 

state and local plumbing codes. 

 

NOTE

: Some codes may require installation by a 

licensed plumber; check with the local plumbing 

authority prior to installation. 

  In restricted under–sink areas, it may be easier to 

install the faucet first. Allow adequate tubing lengths 

for any final component position. 

A.  Faucet With Water Quality Monitor (Optional) 

Installation  

The faucet contains an anti–siphon air gap. 

While the system is producing water, the drain 

water flows from the R.O., through the air gap 

and then to the household drain. The purpose of 

the air gap is to prevent water in the drain from 

backing up into the R.O. Drinking Water System. 

  The easiest installation is to use an existing 

spray attachment hole. If the spray faucet hole is 

not available, then the sink top must be drilled. 

Choose a convenient location as described in  

Sec. III, C.1.
1.  Mark the location of the center of the faucet 

base. 

2a. Drilling a stainless steel sink: 

•Center punch the hole to provide a starting 

point for the drill. 

•Start with a smaller drill as a pilot, and then 

drill a ½" diameter hole to accept the bolt of 

a 1¼" Greenlee Hole Punch (1¼" chassis 

punch). 

•Clean away any chips. 
•Install the punch and tighten the nut to cut 

the hole. 

•Deburr any sharp edges. 

2b. Drilling a porcelain sink: 
  It is best to use a special 1¼" diameter cutter 

designed for porcelain. A carbide tipped 

masonry bit is a second choice. 
•Place a piece of tape over the area to be 

drilled to help prevent chipping. 

•Drill a pilot hole for the porcelain cutter. 

Use the pilot drill supplied with the kit or a 

carbide tipped drill. 

•When drilling the 1¼" hole, drill slowly and 

carefully; the porcelain chips easily. 

•After drilling, clean the area well. Iron filings, 

if left in place, can cause rust stains. 

2c. Drilling a counter top: 
 

NOTE:

 The counter top must be less than 

1¼" thick. Treat ceramic tile as porcelain until 

the tile is penetrated, then use the carbide 

tipped metal cutter. 

  Formica counter tops may be drilled with a 

good 1¼" wood bit; drilling a 

3

/

32

" pilot hole 

will help keep the bit going straight.

3. The hole in the Monitor Housing should be 
centered on the mounting hole. If cutting or drilling 
a mounting hole, please note that the Monitor 
Housing is elliptical and the hole which runs through 
it is off center from front to back.

4. Feed the Monitor Cord through the 1 ¼”diameter 
Monitor Housing opening so that it is positioned 
above the Monitor Housing.

Assemble the 1/8” Screws & Toggle Wings into the 
Monitor Housing. Adjust the Wings approximately 
1” plus the thickness of the mounting surface away 
from the bottom of the Monitor Housing.

Summary of Contents for PURO-35T

Page 1: ...Tested and Certified by NSF International against NSF ANSI Standard 58 for the reduction of the claims specified on the Performance Data Sheet MODEL PURO 35T INSTALLATION OPERATION SERVICE MANUAL ...

Page 2: ...ertains to people with HIV AIDS patients receiving treatment for cancer recipients of organ or bone marrow transplants transplant patients taking immunosuppressive drugs and persons who have congenital immunodeficiencies The EPA has stated that they do not know the significance of drinking water compared to other possible sources of Cryptosporidium to determine how most people become infected The ...

Page 3: ...duct water tank is full and closes the feed water supply to prevent excess reject water from going to drain when the unit is not producing water WATER QUALITY MONITOR The Water Quality Monitor has been integrated into the faucet base for instant monitoring at the touch of a button The monitor compares the level of the Total Dissolved Solids in the incoming feed water versus the product water and c...

Page 4: ...t is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage This reverse osmosis system contains a replaceable...

Page 5: ...e screws and nuts for mounting the manifold or concrete anchors for hanging on basement wall Additional tubing or tube connectors Plastic wire ties for organizing tubing TYPICAL PURO 35T UNDER SINK INSTALLATION DIAGRAM Figure 1 Dispensing Faucet with Air gap drain clamp drain 3 8 Black PRODUCT 3 8 Blue drain 1 4 Black INLET 1 4 Red TANK 3 8 Yellow DRINKING WATER HOLDING TANK HOLDING TANK SHUTOFF V...

Page 6: ... POST FILTER HOUSING sediment carbon PREFILTER HOUSING BASEMENT FLOOR please note if air gap in faucet is not used in basement installations a proper air gap must be created please check with local plumbing codes see example above FLOOR FEED water saddle valve cold water line only INLET 1 4 Red DRAIN 1 4 Black 1 air gap required POLYTUBE TEE IN LINE ACTIVATED CARBON POST FILTER 1 4 Yellow Water qu...

Page 7: ...en area beneath the faucet under the sink for attaching product and drain tubing are considerations A 2 diameter flat surface is required above and below the installation site The thickness of the mounting surface should not exceed 1 Watch for strengthening webbing on the underside of cast iron sinks 2 Drinking Water Holding Tank The Holding Tank may be placed where it is convenient within 10 feet...

Page 8: ...ps Install the punch and tighten the nut to cut the hole Deburr any sharp edges 2b Drilling a porcelain sink It is best to use a special 1 diameter cutter designed for porcelain A carbide tipped masonry bit is a second choice Place a piece of tape over the area to be drilled to help prevent chipping Drill a pilot hole for the porcelain cutter Use the pilot drill supplied with the kit or a carbide ...

Page 9: ...LYTUBE PRODUCT OUTLET 6 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fitting Push the Black 3 8 Polytube onto the large Hose Barb Push the Black Polytube onto the small Hose Barb 7 Determine which direction the handle should face right or left With the handle facing the chosen direction slide the fastened Polytubes through the Monitor Housings 1 diameter o...

Page 10: ...e hole so that the lance fits into the hole Assemble and tighten the brass screw Turn the Valve Handle clockwise inward until firmly seated The valve is closed 3 With the Feed Water Saddle Valve closed open the sink faucet and the water supply and allow the water to run for a few minutes to flush any debris caused by the installation Close the faucet and check the Feed Water Saddle Valve for leaks...

Page 11: ...ain port on the manifold will have a drain restrictor in it Remove the black plug from the fitting labeled Drain on the manifold and insert the tubing Allow the tubing to relax then press firmly again to insure proper seating 4 Locate the yellow tubing with the tee attached to one end Remove the yellow plug from the fitting labeled Out on the manifold and insert the tubing 5 Locate the 3 8 Blue Pr...

Page 12: ...d open the Dispensing Faucet Allow the Holding Tank to completely drain Then remove the Activated Carbon Prefilter Housing the one closest to the In Out ports empty and install the Activated Carbon Prefilter Firmly tighten the Housing hand tight only 2 Installing the R O Membrane Remove the R O Membrane Housing the middle one and empty Insert the Membrane up into the manifold The O rings should be...

Page 13: ...er Housings are removed Refer to Fig 1 for component location 1 Close the Feed Water Saddle Valve by turning fully clockwise and open the Dispensing Faucet Allow the Holding Tank to empty 2 Loosen and remove the Sediment Carbon Prefilter and the Activated Carbon Post Filter Housings Discard the filters 3 Wash the inside of the Housings using a mild detergent and a soft cloth Do not use abrasive cl...

Page 14: ... Close the Holding Tank Valve and then open the Dispensing Faucet to release the pressure 3 Remove the In Line Activated Carbon Post Filter Disconnect the used Post Filter by pressing in the connector s collar and at the same time pulling the tube out of the fitting 4 Firmly reconnect the polytubes to the new Post Filter Refer to Fig 5 Make sure the tubing is pressed all the way in to create a pre...

Page 15: ...15 NOTES ...

Page 16: ...ee check The ASO Valve is malfunctioning Replace ASO Valve components Low pressure at the Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Holding Tank is too low Empty water from Holding Tank and with the faucet open adjust the air pressure to 5 7 psig 35 48 kPa range Check for leakage at the Air Valve Stem Holding Tank Valve is partially ...

Page 17: ... are reversed Correct plumbing Dissolved gasses in the Feed Water Pretreat Feed Water to remove dissolved gasses Increase in Product Water TDS See high TDS in the Product Water section Drain Water overflows at the Dispensing Faucet Air Gap is blocked Clear Air Gap Rinse with vinegar for removal of calcium buildup Drain tubing is clogged Clear tubing Drain Clamp hole is misaligned Align with hole i...

Page 18: ...18 Exploded View Parts List MADE IN USA 19 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 18 16 17 21 Nitrate Nitrite Test Kit ...

Page 19: ... 15 R7078 Water Quality Monitor w Probes and Cover 16 S2116 5 Drain Restrictor 50 GPD 189 lpd 17 S7125 Activated Carbon Post Filter 18 S1405 1 4 3 8 Fitting Wrench 19 S3072 Wrench for Housing 20 S7206W JG In Line Activated Carbon Post Filter shown on pg 6 R2118 Water Quality Monitor 25 Ft Extension Cable 21 S1447 Nitrate Nitrite Test Kit OTHER COMPONENTS AS SHOWN IN FIGURE 1 PAGE 5 DRAWING NO PART...

Page 20: ...sediment and carbon filters whose service life depends on feed water conditions In addition the membrane is only warranted if the required feed water conditions are met The above warranty will also not apply to any part of the Master Water Conditioning R O Drinking Water System that is damaged because of neglect misuse alterations accident misapplication physical damage or damage caused by fire ac...

Reviews: