Puro PURO-35T Installation, Operation & Service Manual Download Page 7

7

B.  Tools Recommended for Installation 

  The following tools will cover most of the 

installation sites encountered:
1. 

3

/

8

" variable speed electric drill.

2.  Extension work light with outlet.
3.  Safety glasses.
4.  1¼" porcelain hole cutter kit.
5.  1¼" Greenlee hole punch and 

1

/

8

" and 

½" metal drill bits for pilot hole. 

6.  Center punch and hammer.
7.  1¼" wood bit.
8.  Concrete drill bits.
9.  Assorted wood and metal drill bits including 

 

7

/

32

" metal drill bit. 

10. Phillips head and flat blade screwdrivers.
11. ½", 

9

/

16

" and 

5

/

8

" open end wrenches.

12. Teflon tape. 
13. Wide masking tape or duct tape. 
14. Plastic tubing cutter. 
15. Extra plastic tubing.
16. Low range air pressure gauge. 
17. Bicycle hand air pump. 
18. Small bottle of liquid chlorine bleach. 
19. Graduated measuring cylinder. 
20. Paper towels, wisk broom and assorted clean 

up materials.

C.  Site Selection for Major System Components 

  The R.O. System was designed to fit under a 

sink, however, because of space limitations 

or other reasons, the system’s flexible design 

allows for other locations. When determining the 

location remember that access to a cold water 

tap line, the household drain, and ease of filter 

replacement are important considerations. 

  All components and tubing should be located in 

an area not exposed to freezing temperatures. If 

winter temperatures are severe, the area should 

be above the minimum temperature listed in 

Table B for proper performance. Do not expose 

unit or tubing to direct sunlight. 

1.  Dispensing Faucet–

The faucet should be 

placed near the sink where drinking water 

is normally obtained. Convenience of use 

(filling of water pitchers and glasses), and 

an open area beneath the faucet under the 

sink for attaching product and drain tubing 

are considerations. A 2" diameter flat surface 

is required above and below the installation 

site. The thickness of the mounting 

surface should not exceed 1¼". Watch for 

strengthening webbing on the underside of 

cast iron sinks. 

2.  Drinking Water Holding Tank–

The Holding 

Tank may be placed where it is convenient 

within 10 feet of the faucet; under the sink or 

in an adjacent cabinet are best the choices. 

If a longer run of tubing is required, the 

tubing should be the 

3

/

8

" diameter OD size 

to prevent a high pressure drop. Remember, 

these tanks can weigh up to 30 pounds when 

full of water; a firm, level area is required. 

3.  R.O. Manifold Assembly–

The manifold can 

be installed on either the right or left side 

of the under–sink area or a cabinet. The 

right side is recommended because all the 

tubing will be to the back of the cabinet and 

out of the way. Installation in the basement 

is also an option; one location is near the 

laundry/utility sink where cold potable water 

and drain access are handy. The mounting 

location should allow adequate clearance 

and accessibility for cartridge changes. 

4.  Feed Water Connection–

The Feed Water 

Saddle Valve should be located as close to 

the manifold assembly as possible. USE A 

POTABLE COLD WATER SUPPLY ONLY. 

Softened water is preferred as it will extend 

the life of the R.O. Membrane.

5.  Drain Connection–

The waste water must 

go to drain through an anti–siphon air gap. 

The air gap is provided for in the base of 

the faucet. If discharging into a utility sink 

or standpipe, an air gap of greater than 1" 

above the flood rim must be provided. 

  Do NOT connect the system drain line to 

the dishwasher drain or near the garbage 

disposal. Backpressure from these units may 

cause the air gap to overflow.

Summary of Contents for PURO-35T

Page 1: ...Tested and Certified by NSF International against NSF ANSI Standard 58 for the reduction of the claims specified on the Performance Data Sheet MODEL PURO 35T INSTALLATION OPERATION SERVICE MANUAL ...

Page 2: ...ertains to people with HIV AIDS patients receiving treatment for cancer recipients of organ or bone marrow transplants transplant patients taking immunosuppressive drugs and persons who have congenital immunodeficiencies The EPA has stated that they do not know the significance of drinking water compared to other possible sources of Cryptosporidium to determine how most people become infected The ...

Page 3: ...duct water tank is full and closes the feed water supply to prevent excess reject water from going to drain when the unit is not producing water WATER QUALITY MONITOR The Water Quality Monitor has been integrated into the faucet base for instant monitoring at the touch of a button The monitor compares the level of the Total Dissolved Solids in the incoming feed water versus the product water and c...

Page 4: ...t is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage This reverse osmosis system contains a replaceable...

Page 5: ...e screws and nuts for mounting the manifold or concrete anchors for hanging on basement wall Additional tubing or tube connectors Plastic wire ties for organizing tubing TYPICAL PURO 35T UNDER SINK INSTALLATION DIAGRAM Figure 1 Dispensing Faucet with Air gap drain clamp drain 3 8 Black PRODUCT 3 8 Blue drain 1 4 Black INLET 1 4 Red TANK 3 8 Yellow DRINKING WATER HOLDING TANK HOLDING TANK SHUTOFF V...

Page 6: ... POST FILTER HOUSING sediment carbon PREFILTER HOUSING BASEMENT FLOOR please note if air gap in faucet is not used in basement installations a proper air gap must be created please check with local plumbing codes see example above FLOOR FEED water saddle valve cold water line only INLET 1 4 Red DRAIN 1 4 Black 1 air gap required POLYTUBE TEE IN LINE ACTIVATED CARBON POST FILTER 1 4 Yellow Water qu...

Page 7: ...en area beneath the faucet under the sink for attaching product and drain tubing are considerations A 2 diameter flat surface is required above and below the installation site The thickness of the mounting surface should not exceed 1 Watch for strengthening webbing on the underside of cast iron sinks 2 Drinking Water Holding Tank The Holding Tank may be placed where it is convenient within 10 feet...

Page 8: ...ps Install the punch and tighten the nut to cut the hole Deburr any sharp edges 2b Drilling a porcelain sink It is best to use a special 1 diameter cutter designed for porcelain A carbide tipped masonry bit is a second choice Place a piece of tape over the area to be drilled to help prevent chipping Drill a pilot hole for the porcelain cutter Use the pilot drill supplied with the kit or a carbide ...

Page 9: ...LYTUBE PRODUCT OUTLET 6 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fitting Push the Black 3 8 Polytube onto the large Hose Barb Push the Black Polytube onto the small Hose Barb 7 Determine which direction the handle should face right or left With the handle facing the chosen direction slide the fastened Polytubes through the Monitor Housings 1 diameter o...

Page 10: ...e hole so that the lance fits into the hole Assemble and tighten the brass screw Turn the Valve Handle clockwise inward until firmly seated The valve is closed 3 With the Feed Water Saddle Valve closed open the sink faucet and the water supply and allow the water to run for a few minutes to flush any debris caused by the installation Close the faucet and check the Feed Water Saddle Valve for leaks...

Page 11: ...ain port on the manifold will have a drain restrictor in it Remove the black plug from the fitting labeled Drain on the manifold and insert the tubing Allow the tubing to relax then press firmly again to insure proper seating 4 Locate the yellow tubing with the tee attached to one end Remove the yellow plug from the fitting labeled Out on the manifold and insert the tubing 5 Locate the 3 8 Blue Pr...

Page 12: ...d open the Dispensing Faucet Allow the Holding Tank to completely drain Then remove the Activated Carbon Prefilter Housing the one closest to the In Out ports empty and install the Activated Carbon Prefilter Firmly tighten the Housing hand tight only 2 Installing the R O Membrane Remove the R O Membrane Housing the middle one and empty Insert the Membrane up into the manifold The O rings should be...

Page 13: ...er Housings are removed Refer to Fig 1 for component location 1 Close the Feed Water Saddle Valve by turning fully clockwise and open the Dispensing Faucet Allow the Holding Tank to empty 2 Loosen and remove the Sediment Carbon Prefilter and the Activated Carbon Post Filter Housings Discard the filters 3 Wash the inside of the Housings using a mild detergent and a soft cloth Do not use abrasive cl...

Page 14: ... Close the Holding Tank Valve and then open the Dispensing Faucet to release the pressure 3 Remove the In Line Activated Carbon Post Filter Disconnect the used Post Filter by pressing in the connector s collar and at the same time pulling the tube out of the fitting 4 Firmly reconnect the polytubes to the new Post Filter Refer to Fig 5 Make sure the tubing is pressed all the way in to create a pre...

Page 15: ...15 NOTES ...

Page 16: ...ee check The ASO Valve is malfunctioning Replace ASO Valve components Low pressure at the Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Holding Tank is too low Empty water from Holding Tank and with the faucet open adjust the air pressure to 5 7 psig 35 48 kPa range Check for leakage at the Air Valve Stem Holding Tank Valve is partially ...

Page 17: ... are reversed Correct plumbing Dissolved gasses in the Feed Water Pretreat Feed Water to remove dissolved gasses Increase in Product Water TDS See high TDS in the Product Water section Drain Water overflows at the Dispensing Faucet Air Gap is blocked Clear Air Gap Rinse with vinegar for removal of calcium buildup Drain tubing is clogged Clear tubing Drain Clamp hole is misaligned Align with hole i...

Page 18: ...18 Exploded View Parts List MADE IN USA 19 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 18 16 17 21 Nitrate Nitrite Test Kit ...

Page 19: ... 15 R7078 Water Quality Monitor w Probes and Cover 16 S2116 5 Drain Restrictor 50 GPD 189 lpd 17 S7125 Activated Carbon Post Filter 18 S1405 1 4 3 8 Fitting Wrench 19 S3072 Wrench for Housing 20 S7206W JG In Line Activated Carbon Post Filter shown on pg 6 R2118 Water Quality Monitor 25 Ft Extension Cable 21 S1447 Nitrate Nitrite Test Kit OTHER COMPONENTS AS SHOWN IN FIGURE 1 PAGE 5 DRAWING NO PART...

Page 20: ...sediment and carbon filters whose service life depends on feed water conditions In addition the membrane is only warranted if the required feed water conditions are met The above warranty will also not apply to any part of the Master Water Conditioning R O Drinking Water System that is damaged because of neglect misuse alterations accident misapplication physical damage or damage caused by fire ac...