EN
Operating Manual: PX-iP - Gateway
EN
25
(A)
(A)
Signal LED of radio button
(A) "Off"
(3)
Reset network
f
Press gateway button (B) until a long
acoustic signal is emitted, then release
(B)
5
Gateway is switched off
5.2 Smoke alarm device reset
In order to re-create the radio group
after the gateway reset, also reset the
smoke alarm devices.
(1)
Pull out activation button
(2)
Press and hold Test/Stop button for
2 to 3 seconds
Soft ticking for about
2 seconds
(3)
Press radio button with splint pin
until it flashes, then release
5
The device is in its default state