Servicing
Servicing
Periodically clean the aerator for any lodged sediment that may restrict flow. A Puretec water
filter is highly recommended on all incoming lines for product longevity.
Should it be necessary to have your mixer serviced while under warranty, please carry out the
following procedure:
1.
Firstly call the plumber, preferably the one that has installed it, (most problems are
caused by the supply lines not being cleaned out properly, prior to connecting the
mixers).
2.
Make sure that the plumber has installed your mixer according to the Instruction Guide.
3.
If the plumber is satisfied that he cannot rectify the problem then contact your
plumbing supply store or your local Puretec stockist.
Important
: We do not recommend the dismantling of any internal part of the mixer as
this will breach your warranty.
Technical Information
Puretec mixers can be used in conjunction with:
•
Pressure storage hot water system
•
Any mains water pressure not exceeding 500 kPa
•
Maximum hot water temperature of 60°C
•
Instantaneous hot water system
•
Any filtered water supply
Recommended Working Pressures
•
Minimum working pressure 172 kPa (7.5 psi)
•
Maximum working pressure 500 kPa (72.5 psi)
It should be noted that water mains pressure builds up during off peak periods, mainly at
night, sometimes doubling or trebling normal daytime pressures.
Note
: Not suitable for unequal pressure. On high pressure areas where the pressure exceeds
the recommended working pressure as indicated above, an approved pressure limiting valves
must be installed or warranty is voided.