SOL-TA Commercial Series User Guide
3. Allows selection of one of the follwing using ▲ or ▼:
• An outside signalto initiate a regeneration; or
• An outside signal to prevent or delay regeneration.
Selection only matters if a connection is made to the two pin
connector labelled DP SWITCH located on the printed circut
board.
•
oFF (default) :
Feature not used.
Note:
In a twin alternating system each control must have a
seperate dP signal or dP switch. One dP signal or one dP switch
cannot be used for both controls.
• dPon0:
If the dP switch is closed for an accumulative
time of 2 minutes, a regeneration will will be signalled
to the unit. The MAV will transition first to switch units
so that the signaled unit can start regeneration. After
the MAV has fully transitioned, the regeneration begins
immediately.
• dPdEL:
If the switch is closed for an accumalative time
of 2 minutes a regeneration will occur at the scheduled
delayed regeneration time. Once the dP switch is triggered
the PC board will display REGEN TODAY and switch tanks
immediately. At the delayed regeneration time, the
triggered unit will then regenerate.
Note:
If the dP function 'dPon0' or 'dPdEL' is set, the delayed rinse
and fill feature is not available.
• HoLd:
If the dP switch is closed a regeneration will be
prevented from occurring while there is switch closure.
The regeneration of a unit can be prevented upon switch
closure. If the unit depletes the capacity down to zero, it
will not be allowed to switch tanks to regenerate until the
switch is open. The delayed rinse and fill feature can be
set in conjunction with the 'HoLD' if desired.
Press NEXT to go to step 4.
4. Preset to default. Press NEXT to go to step 5.
Step 4CS
Step 5CS
EXIT TO DISPLAY SCREENS
Step 6CS
Step 7CS
Step 2S
Step 1S
Step 3S
Step 4S
Step 5S
Step 6S
Step 7S
Step 8S
DP Switch Programming