SOL-TA Commercial Series User Guide
12.
Set Regeneration Time Options
using ▲ or ▼. If value is
set to:
• NORMAL:
Means regeneration time will be triggered by
the value specified (in M
3
).
• on O (default) :
Means regenration will occur
immediately when the volume capacity reaches 0 (zero);
or
• on O:
Means regeneration will occur at one of
the following:
- The preset time when the volume capacity falls below
the reserve or the specified number of days between
regenerations is reached whichever comes first; or
- Immediately after 10 minutes of no water usage when
the volume capacity reaches 0 (zero).
Note:
'on 0' is the default if step 2 in DP Switch Programming is
set to 1.0, and ' on O' is not available. This step will not
appear if step 11 is set to 'oFF'.
Press NEXT to go to step 13.
13.
Set Relay Operation
using ▲ or ▼. The choices are:
• Set Time On:
Relay activates after a set time at the
beginning of a regeneration and then deativates after a
set period of time. The start of regeneration is defined
as the first backwash cycle or Dn brine cycle., whichever
comes first.
• Set Litres Softening On:
Replay activates after a set
number of litres have been used while in service and then
deactivates after a set period of time or after the meter
stops registering flow, whichever comes first.
• Set Litres Softening Regen On:
Relay activates after
a set number of litres have been used while in service or
during a regeneration and then deactivates after a set
period of time or after the meter stops registering flow,
whichever comes first.
• ERROR:
Relay closes whenever the value enters error
mode, and immediately deativates when error mode is
exited. If set to ERROR, steps 14 & 15 will not be shown.
• Off (default):
If set to 'oFF", steps 14 & 15 will not be
shown.
Press NEXT to go to step 14.
Step 4S
Step 5S
Step 6S
Step 7S
Step 8S
Step 12S
Step 13S
Step 14S
Step 15S
EXIT OEM SOFTENER SYSTEM SETUP
Step 4I
Step 5I
Step 6I
EXIT INSTALLER DISPLAY SETTINGS
Step 2S
Step 3S
Step 4S
Step 5S
Step 6S
Step 7S
Step 8S
Step 10S
Step 11S
Step 12S
Step 13S
Step 14S
Step 15S
EXIT OEM SOFTENER SYSTEM SETUP
Step 3I
Step 4I
Step 5I
Step 6I
EXIT INSTALLER DISPLAY SETTINGS
Step 10S
Step 11S
Step 12S
Step 13S
Step 9S
Step 14S
Step 15S
EXIT OEM SOFTENER SYSTEM SETUP
Step 1I
Step 2I
Step 3I
Step 4I
Step 5I
Step 6I
EXIT INSTALLER DISPLAY SETTINGS
Step 2S
Step 1S
Step 3S
Step 4S
Step 5S
Step 6S
Step 7S
Step 8S
Step 10S
Step 11S
Step 12S
Step 13S
Step 9S
Step 14S
Step 15S
EXIT OEM SOFTENER SYSTEM SETUP
Step 1I
Step 2I
Step 3I
Step 4I
Step 5I
Step 6I
EXIT INSTALLER DISPLAY SETTINGS
Flashes between these screens.
Advanced Programming
Summary of Contents for SOL-TA Series