Installation Procedure

Installation Procedure

1.  Select suitable location that is close to the existing tap. Remember to allow access 

room for changing filter and a suitable place where water spillage will not cause 

damage. Location should not be in direct sunlight.

2.  Isolate water supply and release water pressure by operating faucet lever. Disconnect 

existing braided hose connections from the cold water line.

3.  Attach non-return valve to water supply with thread seal tape. Then detach the 1/2" 

DR Brass adaptor from the non-return valve, apply thread seal tape as necessary and 
reconnect to the non-return valve.

4.  Install filter cartridge to the head assembly (see Fig. 1). Please note the arrow on the 

cartridge label indicates Undo and Install directions.

5.   Push the joint brass/stem adaptors into the inlet and outlet of the cartridge head, 

ensuring they are pushed in all the way.

6.  Install system assembly by positioning it in the desired location, marking the position 

of fixing holes and fixing with mounting screws (PureMix Z Series can be mounted 
horizontally and vertically). Allow room for the connecting tubes and for removing the 

cartridge (70 mm).

7.  Connect the braided hose onto brass adaptor, then connect to the cartridge head 

assembly inlet (please note the arrow on the head indicating the direction of the water 

flow). A hose extension kit has been provided if necessary, this can be used to extend 

the hose either side of the system. Ensure the hose is kink free.

8.  Connect the mixer tap's braided hose to the brass adaptor on the head outlet. Make 

sure all fittings are tight and braided hose is kink free.

9.  Restore the water supply and check for leaks. If leaking occurs then undo cartridge and 

check the cartridge is seated properly.

10. Run the system for at least 10 minutes (turn on mixer tap to run cold water) to remove 

carbon fines. Water may appear milky, but this is normal and is only tiny air bubbles 
that will clear after a short period.

Summary of Contents for PureMix Z6

Page 1: ...497 Licence No WM 74617 Australian Certification Services User Guide High Flow Inline Water Filter System PureMix Z6 Z7 For correct operation installation it is essential to observe these instructions JUNE2019 ...

Page 2: ...uretec PureMix Inline Water Filter System Your system is a proven performer manufactured from only quality materials and components and will give years of spring fresh water if maintained properly The Puretec PureMix Inline Water Filter System cartridge needs replacing regularly to maintain optimum performance This is a simple procedure when following instructions For cartridge replacements contac...

Page 3: ...u can obtain replacement cartridges from your local Puretec dealer To maintain performance standards and warranty use only genuine Puretec replacements Replacement cartridge code for Z6 model Puretec Z6 R Replacement cartridge code for Z7 model Puretec Z7 R Installation This system comes complete with an installation kit enabling it to be connected to 15mm male thread to an existing tap or mixer t...

Page 4: ...suring they are pushed in all the way 6 Install system assembly by positioning it in the desired location marking the position of fixing holes and fixing with mounting screws PureMix Z Series can be mounted horizontally and vertically Allow room for the connecting tubes and for removing the cartridge 70 mm 7 Connect the braided hose onto brass adaptor then connect to the cartridge head assembly in...

Page 5: ...allation Procedure Figure 1 Head Assembly Also includes Extending Kit Existing Mixer Tap Z6 R Z7 R Cartridge HOT COLD Braided Hose Non Return Valve 1 2 DR Brass Adaptor Brass Adaptor Stem Adaptor Brass Adaptor Stem Adaptor Minimum 70 mm Clearance ...

Page 6: ...idelines Use for mains water supply Minimum operating pressure 200 kPa Maximum operating pressure 689 kPa Do not allow exposure to temperatures below 0 C protect from freezing Maximum operating temperature 38 C Nominal flow rate 9 5 Lpm This system must be installed according to local plumbing codes on the cold water line only This system requires regular replacement of the filter cartridge to mai...

Page 7: ... the domestic water treatment appliance Standards AS NZS3497 for the following water treatment processes Class Treatment type Function Pass I Microbiological Status Bacteriostatic Will stop bacteria increasing but will not remove them unless II a is passed N A II Microbiological Treatment II a Bacteria Removal Will remove or inactivate bacteria N A II b Virus Removal Will remove or inactivate viru...

Page 8: ...omestic water treatment appliance Standards AS NZS3497 for the following water treatment processes Class Treatment type Function Pass I Microbiological Status Bacteriostatic Will stop bacteria increasing but will not remove them unless II a is passed N A II Microbiological Treatment II a Bacteria Removal Will remove or inactivate bacteria N A II b Virus Removal Will remove or inactivate virus N A ...

Page 9: ...se 10 year warranty is 1 year parts and labour plus 9 years parts only Excludes cartridges To make a claim under the warranty take the product and proof of purchase to place where you purchased the product and they will lodge a Warranty Request with Puretec Puretec will pay your reasonable direct expenses of claiming under this warranty You may submit details and proof of your expense claim to pla...

Page 10: ...o have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Warranty New Zealand This warranty is given by Puretec Ltd Reg No 4464398 PO Box 875 Cambridge 3450 NZ telephone no 0800 130 140 and email at sales puretec co nz This warranty is provided in addition to other rights and remedies you have under law Our goods come wi...

Page 11: ...11 High Flow Inline Water Filter Systems This page was intentially left blank ...

Page 12: ......

Reviews: