PRO SERIES Drinking Water Systems
USER GUIDE
PRO SERIES Drinking Water Systems
Copyright © Fluid Products Pty Ltd 2012
4
INSTALLATION PROCEDURE -
See Figure 1
1.
The unit comes with a Tap Adapter on the inlet side, identified by GREEN hose, which will
screw onto a standard tap without the need of thread seal tape. Make sure it is firmly screwed
to provide a seal on the rubber gasket (hand tighten only).
2.
To gain access to the mounting screw holes on the mounting bracket, simply unclip the
R.O. housing from the clip attached to the main mounting bracket. This will reveal the wall
mounting screw holes to enable the mounting of the system to the wall, cupboard etc.
3.
Purified water (BLUE hose), and waster water (BLACK hose) lines do not come with any
attachments. Pure water should be directed to a suitable container without any back pressure
or valving occurring in the line. The drain line, or waste water may be directed to the outside
garden, or if installed inside, to a washing machine, to conserve water. If inconvenient it may
be directed to any drainage system.
4.
When the unit is in place and the water lines are installed, the unit should be run for four (4)
hours before the purified water is used, on initial start up. The unit cannot be stored for more
than two weeks without use, or damaged to the membrane may occur. Please enquire if this is
the case.
For a period of non-use greater than 2 days, flush for 10 min before use. For non-use greater
than 2 weeks, the cartridges may need replacing.
5.
The Sediment and Chemical Removal Filters should be replaced every six (6) months. The
membrane should be replaced when water quality deteriorates or every 18-24 months,
depending on incomming water quality.
A Puretec TDS meter (PTE10) can determine quality
for you at the push of a button.
For best performance use only genuine Puretec replacement cartridges and cartridges that are
suitable for this appliance.